Analysis on Fracture Failure of Mixer Top Cover

The AlSi7Mg1A Al alloy top cover of a mixer fractured in use. Metallographic microscope, Vickers hardness tester, pH value tester and SEM were used to detect and analyze the fracture reason. Results showed that the hardness, composition and metallographic structure of the top cover met the technical...