Reporting Clinical Results of EPID-Based Patient-Specific Quality Assurance for Brain Stereotactic Radiosurgery/Radiation Therapy: Demonstrating the Feasibility of Same-Day Stereotactic Radiosurgery via HyperArc Delivery
Purpose: Patient-specific quality assurance (PSQA) of complex volumetric modulated arc therapy plans via Electronic portal imaging device (EPID)-based portal dosimetry (PD) is widely adopted by the radiation therapy community. We report our EPID-based PSQA results for brain HyperArc stereotactic rad...