Investigating Direct Torque Control of Six-Phase Induction Machines Under Open Phase Fault Conditions
This paper presents analysis and evaluation of classical direct torque control(DTC), for controlling a symmetrical six phase induction motor (SPIM) under open phasefault conditions. The machine has two three-phase windings spatially shifted by 60 electricaldegrees. The strategy of the proposed metho...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Amirkabir University of Technology
2017-12-01
|
Series: | AUT Journal of Electrical Engineering |
Subjects: | |
Online Access: | https://eej.aut.ac.ir/article_1974_d089edf0b2460c10b04eb1be568c6025.pdf |
Tags: |