Cause Analysis of External Corrosion Perforation Failure of P110 Tubing in a Water Injection Well

The macromorphology, material properties and corrosion products composition of the corrosive perforated P110 tubing in a water injection well were characterized. Combined with the investigation of service conditions and tubing neutral point calculation, the reason of external corrosion perforation i...

Full description

Saved in:
Bibliographic Details
Main Author: LI Fang, YANG Zhi-wen, ZENG Wen-guang, GAO Liang, ZHANG Jiang-jiang, ZHANG Lei, LU Min-xu
Format: Article
Language:Chinese
Published: Editorial Department of Materials Protection 2021-07-01
Series:Cailiao Baohu
Subjects:
Online Access:http://www.mat-pro.com/fileup/1001-1560/PDF/20210728.pdf