Management and Outcomes of Breakage in Polyethylene-Ceramic Composite (Sandwich-type) Liners: Lessons From Long-term Follow-up
This case series reports the only 3 instances of ceramic liner breakage among patients who underwent total hip arthroplasty (THA) with polyethylene–ceramic composite (sandwich-type) liners at our center between 1999 and 2002. Breakages occurred at approximately 6 (n = 2) and 17 years (n = 1) after t...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-06-01
|
Series: | Arthroplasty Today |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2352344125000858 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This case series reports the only 3 instances of ceramic liner breakage among patients who underwent total hip arthroplasty (THA) with polyethylene–ceramic composite (sandwich-type) liners at our center between 1999 and 2002. Breakages occurred at approximately 6 (n = 2) and 17 years (n = 1) after the primary THA. Symptoms included audible crepitation, pain, and restricted motion during normal activities. Surgical revisions utilized a polyethylene liner and third-generation alumina ceramic head, with synovectomy and irrigation to remove debris (preventing third-body wear). All patients achieved good long-term outcomes. Although infrequent, the risk of breakage increases over time, and several patients still carry these liners years after THA. This case series underscores the importance of vigilant follow-up, patient education, and timely intervention to manage this infrequent but potentially catastrophic complication. |
---|---|
ISSN: | 2352-3441 |