Results of correction of aortic valve defects using small‑diameter «BioLAB» xenopericardial prosthesis in old patients

A prosthesis-patient mismatch (PPM) describes a state in which the valve prosthesis implanted during surgery is too small in relation to the patient’s body size. This leads to high transvalvular pressure gradients. We investigate direct results and dependence of transvalvular pressure gradients on b...

Full description

Saved in:
Bibliographic Details
Main Authors: S. I. Babenko, R. M. Muratov, T. A. Chabaidze, N. N. Soboleva, M. N. Sorkomov
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2020-04-01
Series:Вестник трансплантологии и искусственных органов
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/1147