EXPERIMENTAL INVESTIGATION OF CRITICAL HEAT FLUX IN ANNULUS AT LOW PRESSURE AND LOW FLOW PARAMETERS
Steady state flow boiling experiments were conducted on a technically smooth Inconel 625 tube with outer diameter 9.1 mm at inlet pressures 131, 220 and 323 kPa, inlet temperatures 62, 78 and 94 °C and approximately 400, 600 and 1000 kg/(m2.s) mass flow. Water of these parameters was entering into t...
Saved in:
Main Authors: | Daniel Vlček, Ladislav Suk, Kamil Števanka, Taron Petrosyan |
---|---|
Format: | Article |
Language: | English |
Published: |
Czech Technical University in Prague
2020-12-01
|
Series: | Acta Polytechnica CTU Proceedings |
Subjects: | |
Online Access: | https://ojs.cvut.cz/ojs/index.php/APP/article/view/6920 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
INVESTIGATION OF CRITICAL HEAT FLUX ON ABRADED INCONEL 625 TUBE
by: Ladislav Suk, et al.
Published: (2020-12-01) -
Heat transfer hysteresis under liquid binary mixtures boiling
by: V. V. Kozhokaru, et al.
Published: (2018-07-01) -
Experimental study on enhanced heat transfer characteristics and flow instability of manifold microchannel
by: Ping Liu, et al.
Published: (2025-09-01) -
Experimental and Numerical Simulation Researches of Critical Heat Flux in Tube under Motion Condition
by: XIA Binzhuo, XIA Fanting, ZHANG Kui, CHEN Ronghua, TIAN Wenxi, QIU Suizheng
Published: (2025-06-01) -
INTERCONNECTION BETWEEN EVAPORATION RATE AND CRITICAL DENSITY OF HEAT FLOW OF BOILING BINARY LIQUID MIXTURES
by: Viktor V. Romanov
Published: (2012-08-01)