Simulation and Validation of Dose Distribution in BNCT Treatment Planning System

The treatment planning system (TPS) of boron neutron capture therapy (BNCT) is a software composed of a series of modules. It is used to evaluate the dose distribution based on medical information and the characteristics of the therapeutic neutron source, assisting physicians in formulating precise...

Full description

Saved in:
Bibliographic Details
Main Author: LYU Tianqi, MENG Siqin, WANG Hongliang, HE Linfeng, RUAN Shihao, WANG Tianyun, WU Meimei, CHEN Jun, SHI Bin, GUAN Fengping, LI Yuqing, LI Tianfu, HAO Lijie, LIU Yuntao
Format: Article
Language:English
Published: Editorial Board of Atomic Energy Science and Technology 2025-01-01
Series:Yuanzineng kexue jishu
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839610970223149056
author LYU Tianqi, MENG Siqin, WANG Hongliang, HE Linfeng, RUAN Shihao, WANG Tianyun, WU Meimei, CHEN Jun, SHI Bin, GUAN Fengping, LI Yuqing, LI Tianfu, HAO Lijie, LIU Yuntao
author_facet LYU Tianqi, MENG Siqin, WANG Hongliang, HE Linfeng, RUAN Shihao, WANG Tianyun, WU Meimei, CHEN Jun, SHI Bin, GUAN Fengping, LI Yuqing, LI Tianfu, HAO Lijie, LIU Yuntao
author_sort LYU Tianqi, MENG Siqin, WANG Hongliang, HE Linfeng, RUAN Shihao, WANG Tianyun, WU Meimei, CHEN Jun, SHI Bin, GUAN Fengping, LI Yuqing, LI Tianfu, HAO Lijie, LIU Yuntao
collection DOAJ
description The treatment planning system (TPS) of boron neutron capture therapy (BNCT) is a software composed of a series of modules. It is used to evaluate the dose distribution based on medical information and the characteristics of the therapeutic neutron source, assisting physicians in formulating precise radiation treatment plans. The TPS enables better tumor control and the protection of normal tissues, thereby enhancing the therapeutic efficacy and reducing side effects, playing a crucial role in ensuring the safety and accuracy of the treatment. With the development of accelerator technology, accelerators-based BNCT has entered the stage of rapid development. However, the development of TPS in China lags, significantly impeding the progress of BNCT clinical applications. In this paper, a program was designed independently using the Python language, which implemented the primary functions of BNCT-TPS, including medical data processing, organizational classification, three-dimensional reconstruction, particle transport simulation, dose distribution output, and data fusion. Interpolation functions and adjustable voxel grids were used to establish a model for patients to meet the requirements of simulation. The dose distribution of the model was simulated using MCNP, and further weighting and adjustments were made in the post-processing software based on the main elements affecting the efficacy of BNCT. Subsequently, the dose results and distribution maps of interest to physicians were overlaid and output with medical images using Python. After the completion of the entire program construction, a reactor neutron source was used to experimentally verify the simulation results of a 3D printed human head model. The distribution of neutron flux inside the human head was measured by activating gold foil and the simulation results were compared against the experimental results. The consistency of the outcomes confirms the validity of the data processing and material conversion method used in this paper. After verifying the function of the program, the dose distribution based on medical datasets of real human heads and neutron sources dedicated to BNCT were simulated. The simulation results show that the energy spectrum of the neutron source has a crucial impact on the therapeutic effect. The fast neutrons in the neutron source interact with the H element, resulting in a high dose on the skin and damaging the normal tissues of the body. The higher content of epithermal neutrons in the neutron source is beneficial for forming a higher thermal neutron fluence at the tumor, which increases the probability of interaction between boron-carrying drugs and thermal neutrons, thereby improving the therapeutic effect. This work establishes a basis for further development of a full-fledged TPS software.
format Article
id doaj-art-edf4db1a1c53423b935c48a22a7bb1c9
institution Matheson Library
issn 1000-6931
language English
publishDate 2025-01-01
publisher Editorial Board of Atomic Energy Science and Technology
record_format Article
series Yuanzineng kexue jishu
spelling doaj-art-edf4db1a1c53423b935c48a22a7bb1c92025-07-29T03:20:16ZengEditorial Board of Atomic Energy Science and TechnologyYuanzineng kexue jishu1000-69312025-01-0159123924610.7538/yzk.2024.youxian.0101Simulation and Validation of Dose Distribution in BNCT Treatment Planning SystemLYU Tianqi, MENG Siqin, WANG Hongliang, HE Linfeng, RUAN Shihao, WANG Tianyun, WU Meimei, CHEN Jun, SHI Bin, GUAN Fengping, LI Yuqing, LI Tianfu, HAO Lijie, LIU Yuntao0China Institute of Atomic Energy, Beijing 102413, ChinaThe treatment planning system (TPS) of boron neutron capture therapy (BNCT) is a software composed of a series of modules. It is used to evaluate the dose distribution based on medical information and the characteristics of the therapeutic neutron source, assisting physicians in formulating precise radiation treatment plans. The TPS enables better tumor control and the protection of normal tissues, thereby enhancing the therapeutic efficacy and reducing side effects, playing a crucial role in ensuring the safety and accuracy of the treatment. With the development of accelerator technology, accelerators-based BNCT has entered the stage of rapid development. However, the development of TPS in China lags, significantly impeding the progress of BNCT clinical applications. In this paper, a program was designed independently using the Python language, which implemented the primary functions of BNCT-TPS, including medical data processing, organizational classification, three-dimensional reconstruction, particle transport simulation, dose distribution output, and data fusion. Interpolation functions and adjustable voxel grids were used to establish a model for patients to meet the requirements of simulation. The dose distribution of the model was simulated using MCNP, and further weighting and adjustments were made in the post-processing software based on the main elements affecting the efficacy of BNCT. Subsequently, the dose results and distribution maps of interest to physicians were overlaid and output with medical images using Python. After the completion of the entire program construction, a reactor neutron source was used to experimentally verify the simulation results of a 3D printed human head model. The distribution of neutron flux inside the human head was measured by activating gold foil and the simulation results were compared against the experimental results. The consistency of the outcomes confirms the validity of the data processing and material conversion method used in this paper. After verifying the function of the program, the dose distribution based on medical datasets of real human heads and neutron sources dedicated to BNCT were simulated. The simulation results show that the energy spectrum of the neutron source has a crucial impact on the therapeutic effect. The fast neutrons in the neutron source interact with the H element, resulting in a high dose on the skin and damaging the normal tissues of the body. The higher content of epithermal neutrons in the neutron source is beneficial for forming a higher thermal neutron fluence at the tumor, which increases the probability of interaction between boron-carrying drugs and thermal neutrons, thereby improving the therapeutic effect. This work establishes a basis for further development of a full-fledged TPS software.boron neutron capture therapytreatment planning systemdosimetry
spellingShingle LYU Tianqi, MENG Siqin, WANG Hongliang, HE Linfeng, RUAN Shihao, WANG Tianyun, WU Meimei, CHEN Jun, SHI Bin, GUAN Fengping, LI Yuqing, LI Tianfu, HAO Lijie, LIU Yuntao
Simulation and Validation of Dose Distribution in BNCT Treatment Planning System
Yuanzineng kexue jishu
boron neutron capture therapy
treatment planning system
dosimetry
title Simulation and Validation of Dose Distribution in BNCT Treatment Planning System
title_full Simulation and Validation of Dose Distribution in BNCT Treatment Planning System
title_fullStr Simulation and Validation of Dose Distribution in BNCT Treatment Planning System
title_full_unstemmed Simulation and Validation of Dose Distribution in BNCT Treatment Planning System
title_short Simulation and Validation of Dose Distribution in BNCT Treatment Planning System
title_sort simulation and validation of dose distribution in bnct treatment planning system
topic boron neutron capture therapy
treatment planning system
dosimetry
work_keys_str_mv AT lyutianqimengsiqinwanghonglianghelinfengruanshihaowangtianyunwumeimeichenjunshibinguanfengpingliyuqinglitianfuhaolijieliuyuntao simulationandvalidationofdosedistributioninbncttreatmentplanningsystem