MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF
The paper analyzes an operation of the standard three-impulse automatic control system (ACS) for steam generator water supply. Mathematical model for checking its operational ability on load relief has been developed in the paper and this model makes it possible to determine maximum deviations of wa...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2014-02-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Subjects: | |
Online Access: | https://energy.bntu.by/jour/article/view/766 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839570640528474112 |
---|---|
author | G. T. Kulakov A. T. Kulakov A. N. Kukharenko |
author_facet | G. T. Kulakov A. T. Kulakov A. N. Kukharenko |
author_sort | G. T. Kulakov |
collection | DOAJ |
description | The paper analyzes an operation of the standard three-impulse automatic control system (ACS) for steam generator water supply. Mathematical model for checking its operational ability on load relief has been developed in the paper and this model makes it possible to determine maximum deviations of water level without execution of actual tests and any corrections in the plants for starting-up of technological protection systems in accordance with water level in the drum. The paper reveals reasons of static regulation errors while solving problems of internal and external distortions caused by expenditure of over-heated steam in the standard automatic control system. An actual significance of modernization pertaining to automatic control system for steam generator water supply has been substantiated in the paper. |
format | Article |
id | doaj-art-eb661d6dca3e4e12866e7b9cfd1d09a5 |
institution | Matheson Library |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2014-02-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-eb661d6dca3e4e12866e7b9cfd1d09a52025-08-04T14:36:04ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412014-02-0101759MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEFG. T. Kulakov0A. T. Kulakov1A. N. Kukharenko2Belarusian National Technical UniversityBelarusian National Technical UniversityCommand and Engineering Institute, Ministry for Emergency Situations of the Republic of BelarusThe paper analyzes an operation of the standard three-impulse automatic control system (ACS) for steam generator water supply. Mathematical model for checking its operational ability on load relief has been developed in the paper and this model makes it possible to determine maximum deviations of water level without execution of actual tests and any corrections in the plants for starting-up of technological protection systems in accordance with water level in the drum. The paper reveals reasons of static regulation errors while solving problems of internal and external distortions caused by expenditure of over-heated steam in the standard automatic control system. An actual significance of modernization pertaining to automatic control system for steam generator water supply has been substantiated in the paper.https://energy.bntu.by/jour/article/view/766mathematical modelregulation errorwater supply |
spellingShingle | G. T. Kulakov A. T. Kulakov A. N. Kukharenko MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика mathematical model regulation error water supply |
title | MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF |
title_full | MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF |
title_fullStr | MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF |
title_full_unstemmed | MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF |
title_short | MATHEMATICAL MODEL OF TRANSIENT PROCESSES PERTAIN-ING TO THREE-IMPULSE SYSTEM FOR AUTOMATIC CONTROL OF STEAM GENERATOR WATER SUPPLY ON LOAD RELIEF |
title_sort | mathematical model of transient processes pertain ing to three impulse system for automatic control of steam generator water supply on load relief |
topic | mathematical model regulation error water supply |
url | https://energy.bntu.by/jour/article/view/766 |
work_keys_str_mv | AT gtkulakov mathematicalmodeloftransientprocessespertainingtothreeimpulsesystemforautomaticcontrolofsteamgeneratorwatersupplyonloadrelief AT atkulakov mathematicalmodeloftransientprocessespertainingtothreeimpulsesystemforautomaticcontrolofsteamgeneratorwatersupplyonloadrelief AT ankukharenko mathematicalmodeloftransientprocessespertainingtothreeimpulsesystemforautomaticcontrolofsteamgeneratorwatersupplyonloadrelief |