SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)

Sensitive potentiometric sensor to ions of lead (II) is made by optimizing the composition of the plasticized membrane. Electrochemical and analytical performance of the electrode are established. The slope of the electrode function is 26,7533 ± 1,09038 mV / dec. The linear range of operation is 0,1...

Full description

Saved in:
Bibliographic Details
Main Authors: K. E. Magomedov, S. D. Tataeva, V. S. Goryachaya
Format: Article
Language:Russian
Published: Dagestan State Technical University 2016-08-01
Series:Вестник Дагестанского государственного технического университета: Технические науки
Subjects:
Online Access:https://vestnik.dgtu.ru/jour/article/view/265
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839576262374326272
author K. E. Magomedov
S. D. Tataeva
V. S. Goryachaya
author_facet K. E. Magomedov
S. D. Tataeva
V. S. Goryachaya
author_sort K. E. Magomedov
collection DOAJ
description Sensitive potentiometric sensor to ions of lead (II) is made by optimizing the composition of the plasticized membrane. Electrochemical and analytical performance of the electrode are established. The slope of the electrode function is 26,7533 ± 1,09038 mV / dec. The linear range of operation is 0,1- 1 • 10-5 M. The ions of zinc, cadmium, mercury, and to a lesser extent copper can have theinterfering effect of the determination of lead ions. Ions of some alkali and alkaline earth metals.do not interfere with the definition.
format Article
id doaj-art-e23ca7d41f0e49c7850323e7f373c8f3
institution Matheson Library
issn 2073-6185
2542-095X
language Russian
publishDate 2016-08-01
publisher Dagestan State Technical University
record_format Article
series Вестник Дагестанского государственного технического университета: Технические науки
spelling doaj-art-e23ca7d41f0e49c7850323e7f373c8f32025-08-04T13:03:18ZrusDagestan State Technical UniversityВестник Дагестанского государственного технического университета: Технические науки2073-61852542-095X2016-08-01321859310.21822/2073-6185-2014-32-1-82-86264SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)K. E. Magomedov0S. D. Tataeva1V. S. Goryachaya2Дагестанский государственный университетДагестанский государственный университетДагестанский государственный университетSensitive potentiometric sensor to ions of lead (II) is made by optimizing the composition of the plasticized membrane. Electrochemical and analytical performance of the electrode are established. The slope of the electrode function is 26,7533 ± 1,09038 mV / dec. The linear range of operation is 0,1- 1 • 10-5 M. The ions of zinc, cadmium, mercury, and to a lesser extent copper can have theinterfering effect of the determination of lead ions. Ions of some alkali and alkaline earth metals.do not interfere with the definition.https://vestnik.dgtu.ru/jour/article/view/265leadelectrodepvc-membrane potentialselectivityionometry
spellingShingle K. E. Magomedov
S. D. Tataeva
V. S. Goryachaya
SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)
Вестник Дагестанского государственного технического университета: Технические науки
lead
electrode
pvc-membrane potential
selectivity
ionometry
title SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)
title_full SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)
title_fullStr SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)
title_full_unstemmed SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)
title_short SENSITIVE POTENTIOMETRIC SENSOR TO IONS OF LEAD (II)
title_sort sensitive potentiometric sensor to ions of lead ii
topic lead
electrode
pvc-membrane potential
selectivity
ionometry
url https://vestnik.dgtu.ru/jour/article/view/265
work_keys_str_mv AT kemagomedov sensitivepotentiometricsensortoionsofleadii
AT sdtataeva sensitivepotentiometricsensortoionsofleadii
AT vsgoryachaya sensitivepotentiometricsensortoionsofleadii