Fracture behavior of multiple adhesive postinstalled anchors subjected to shear force
In this study, experiments were conducted on post-installed anchors subjected to shear force in order to enhance applicability when post-installed anchors were used for seismic reinforcement. Furthermore, since there were a large number of post-installed anchors when they were actually used, an exp...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Czech Technical University in Prague
2022-03-01
|
Series: | Acta Polytechnica CTU Proceedings |
Subjects: | |
Online Access: | https://ojs.cvut.cz/ojs/index.php/APP/article/view/8049 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839596361481191424 |
---|---|
author | Yuji Tajima Kazuaki Hoki |
author_facet | Yuji Tajima Kazuaki Hoki |
author_sort | Yuji Tajima |
collection | DOAJ |
description | In this study, experiments were conducted on post-installed anchors subjected to shear force in order to enhance applicability when post-installed anchors were used for seismic reinforcement. Furthermore, since there were a large number of post-installed anchors when they were actually used, an experiment was conducted in which aăshear force was simultaneously applied to one to four anchors. In this study, it was focused on number and pitch of anchors. Major findings of this study were summarized as follows: in case of 22.46 (N/mm2) for concrete compressive strength, shear strength of anchors was not double, triple, and quadruple as number of those increased to 2, 3, and 4, and that gradually decreased as number of those increased, the boundary condition between anchor shear rupture and pry-out failure was found that concrete compressive strength was 25.12 (N/mm2) or less and anchor pitch was 30 to 50 mm, and anchor was tensile strength over SD390. |
format | Article |
id | doaj-art-df5e9d2936354595bdeaaa9c3fdcb855 |
institution | Matheson Library |
issn | 2336-5382 |
language | English |
publishDate | 2022-03-01 |
publisher | Czech Technical University in Prague |
record_format | Article |
series | Acta Polytechnica CTU Proceedings |
spelling | doaj-art-df5e9d2936354595bdeaaa9c3fdcb8552025-08-02T21:23:56ZengCzech Technical University in PragueActa Polytechnica CTU Proceedings2336-53822022-03-013359760310.14311/APP.2022.33.05975289Fracture behavior of multiple adhesive postinstalled anchors subjected to shear forceYuji Tajima0Kazuaki Hoki1Aichi Syukutoku University, 2-9 Katahira Nagakute-city Aichi Prefecture 480-1197 JapanThe University of Kitakyusyu, 1-1 Hibikino Wakamatu-ku Kitakyusyu-city Fukuoka Prefecture 808-0135 JapanIn this study, experiments were conducted on post-installed anchors subjected to shear force in order to enhance applicability when post-installed anchors were used for seismic reinforcement. Furthermore, since there were a large number of post-installed anchors when they were actually used, an experiment was conducted in which aăshear force was simultaneously applied to one to four anchors. In this study, it was focused on number and pitch of anchors. Major findings of this study were summarized as follows: in case of 22.46 (N/mm2) for concrete compressive strength, shear strength of anchors was not double, triple, and quadruple as number of those increased to 2, 3, and 4, and that gradually decreased as number of those increased, the boundary condition between anchor shear rupture and pry-out failure was found that concrete compressive strength was 25.12 (N/mm2) or less and anchor pitch was 30 to 50 mm, and anchor was tensile strength over SD390.https://ojs.cvut.cz/ojs/index.php/APP/article/view/8049adhesive post-installed anchoranchor pitchmultiple anchorsshear strength |
spellingShingle | Yuji Tajima Kazuaki Hoki Fracture behavior of multiple adhesive postinstalled anchors subjected to shear force Acta Polytechnica CTU Proceedings adhesive post-installed anchor anchor pitch multiple anchors shear strength |
title | Fracture behavior of multiple adhesive postinstalled anchors subjected to shear force |
title_full | Fracture behavior of multiple adhesive postinstalled anchors subjected to shear force |
title_fullStr | Fracture behavior of multiple adhesive postinstalled anchors subjected to shear force |
title_full_unstemmed | Fracture behavior of multiple adhesive postinstalled anchors subjected to shear force |
title_short | Fracture behavior of multiple adhesive postinstalled anchors subjected to shear force |
title_sort | fracture behavior of multiple adhesive postinstalled anchors subjected to shear force |
topic | adhesive post-installed anchor anchor pitch multiple anchors shear strength |
url | https://ojs.cvut.cz/ojs/index.php/APP/article/view/8049 |
work_keys_str_mv | AT yujitajima fracturebehaviorofmultipleadhesivepostinstalledanchorssubjectedtoshearforce AT kazuakihoki fracturebehaviorofmultipleadhesivepostinstalledanchorssubjectedtoshearforce |