Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions

The aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (...

Full description

Saved in:
Bibliographic Details
Main Authors: Kenan G. Elias, Yumen Hilal
Format: Article
Language:English
Published: University of Baghdad, College of Science for Women 2023-04-01
Series:مجلة بغداد للعلوم
Subjects:
Online Access:https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/6860
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839596424350662656
author Kenan G. Elias
Yumen Hilal
author_facet Kenan G. Elias
Yumen Hilal
author_sort Kenan G. Elias
collection DOAJ
description The aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (ICH) requirements. The chromatographic parameters were as follows: column of octyldecylsilyl C18 with dimensions (150 × 4.6) mm, mobile phase composed of acetonitrile with phosphoric acid with a ratio of 50 to 50 each using isocratic mode, flow rate of 1.5 mL/min and injection volume of 5 μL. The detection was carried out using UV detector at 220 nm. The method was validated and showed short retention time for ibuprofen peak at 7.651 min, with linearity in the studied range of 0.4 - 1.6 mg/mL (R2 = 0.9999) and with great accuracy ]percent recovery was (100.48%), percent relative error(-1.511-1.465)%[ and repeatability (RSD% = 0.112 for Retention time). The detection and quantitation limits were determined to be 0.036 and 0.110 mg/mL, respectively. This method was applied successfully to determine the content of ibuprofen in three commercial pharmaceutical products. Looking at the short time of analysis and the low limit detection, we recommend this method for routine assays in the quality control laboratories and as a good method for stability studies of ibuprofen.
format Article
id doaj-art-de3783c6d2f342aab2e9f9f6c3469b29
institution Matheson Library
issn 2078-8665
2411-7986
language English
publishDate 2023-04-01
publisher University of Baghdad, College of Science for Women
record_format Article
series مجلة بغداد للعلوم
spelling doaj-art-de3783c6d2f342aab2e9f9f6c3469b292025-08-02T21:17:28ZengUniversity of Baghdad, College of Science for Womenمجلة بغداد للعلوم2078-86652411-79862023-04-0120210.21123/bsj.2022.6860Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical SuspensionsKenan G. Elias0Yumen Hilal1Department of Pharmaceutical Chemistry and Drug Quality Control, Faculty of Pharmacy, Al-Baath University, Homs, Syria.Department of Pharmaceutical Analytical and Food Chemistry, Faculty of Pharmacy, Al-Baath University, Homs, Syria. The aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (ICH) requirements. The chromatographic parameters were as follows: column of octyldecylsilyl C18 with dimensions (150 × 4.6) mm, mobile phase composed of acetonitrile with phosphoric acid with a ratio of 50 to 50 each using isocratic mode, flow rate of 1.5 mL/min and injection volume of 5 μL. The detection was carried out using UV detector at 220 nm. The method was validated and showed short retention time for ibuprofen peak at 7.651 min, with linearity in the studied range of 0.4 - 1.6 mg/mL (R2 = 0.9999) and with great accuracy ]percent recovery was (100.48%), percent relative error(-1.511-1.465)%[ and repeatability (RSD% = 0.112 for Retention time). The detection and quantitation limits were determined to be 0.036 and 0.110 mg/mL, respectively. This method was applied successfully to determine the content of ibuprofen in three commercial pharmaceutical products. Looking at the short time of analysis and the low limit detection, we recommend this method for routine assays in the quality control laboratories and as a good method for stability studies of ibuprofen. https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/6860Developed, Ibuprofen, Method validation, RP-HPLC, Suspension
spellingShingle Kenan G. Elias
Yumen Hilal
Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
مجلة بغداد للعلوم
Developed, Ibuprofen, Method validation, RP-HPLC, Suspension
title Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
title_full Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
title_fullStr Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
title_full_unstemmed Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
title_short Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
title_sort development and validation of a simple and sensitive reverse phase high performance liquid chromatographic method for the determination of ibuprofen in pharmaceutical suspensions
topic Developed, Ibuprofen, Method validation, RP-HPLC, Suspension
url https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/6860
work_keys_str_mv AT kenangelias developmentandvalidationofasimpleandsensitivereversephasehighperformanceliquidchromatographicmethodforthedeterminationofibuprofeninpharmaceuticalsuspensions
AT yumenhilal developmentandvalidationofasimpleandsensitivereversephasehighperformanceliquidchromatographicmethodforthedeterminationofibuprofeninpharmaceuticalsuspensions