Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation
<p class="Abstract"><a name="OLE_LINK15"></a><a name="OLE_LINK14"></a>Towards the complete vision of smarter distribution grid, advanced distribution automation system (ADAS) is one of the major players in this area. In this scope, this pap...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Academy Publishing Center
2017-03-01
|
Series: | Renewable Energy and Sustainable Development |
Subjects: | |
Online Access: | http://apc.aast.edu/ojs/index.php/RESD/article/view/200 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839635304959442944 |
---|---|
author | M. R. Elkadeem M. A. Alaam Azmy Azmy |
author_facet | M. R. Elkadeem M. A. Alaam Azmy Azmy |
author_sort | M. R. Elkadeem |
collection | DOAJ |
description | <p class="Abstract"><a name="OLE_LINK15"></a><a name="OLE_LINK14"></a>Towards the complete vision of smarter distribution grid, advanced distribution automation system (ADAS) is one of the major players in this area. In this scope, this paper introduces a generic strategy for cost-effective <a name="OLE_LINK555"></a><a name="OLE_LINK554"></a>implementation and evaluation of ADAS. Along with the same line, fault location, isolation and service restoration (FLISR) is one of the most beneficial and desirable applications of ADAS for self-healing and reliability improvement. Therefore, <a name="OLE_LINK24"></a><a name="OLE_LINK23"></a>a <a name="OLE_LINK567"></a><a name="OLE_LINK566"></a>local-centralized-based FLISR (LC-FLISR) <a name="OLE_LINK677"></a><a name="OLE_LINK676"></a>architecture is implemented on a real, urban, underground medium voltage distribution network. For the investigated network, the complete procedure and structure of the LC-FLISR are presented. Finally, the level of reliability improvement and customers’ satisfaction enhancement are evaluated. The results are presented in the form of a comparative study between the proposed automated and non-automated distribution networks. The results show that the automated network with proposed ADAS has a considerable benefit through a significant reduction in reliability indices. In addition, it has remarkable benefits observed from increasing customers’ satisfaction and reducing penalties from industry regulators.</p> |
format | Article |
id | doaj-art-dbaf6ee1df7b4b6bbca4451e4499b444 |
institution | Matheson Library |
issn | 2356-8518 2356-8569 |
language | English |
publishDate | 2017-03-01 |
publisher | Academy Publishing Center |
record_format | Article |
series | Renewable Energy and Sustainable Development |
spelling | doaj-art-dbaf6ee1df7b4b6bbca4451e4499b4442025-07-09T10:32:33ZengAcademy Publishing CenterRenewable Energy and Sustainable Development2356-85182356-85692017-03-0131243210.21622/resd.2017.03.1.02486Reliability Improvement of Power Distribution Systems using Advanced Distribution AutomationM. R. Elkadeem0M. A. Alaam1Azmy Azmy2Elec. Power and Machines Eng. Depart., Faculty of Eng., Tanta University, Tanta, EgyptElec. Power and Machines Eng. Depart., Faculty of Eng., Tanta University, Tanta, EgyptElec. Power and Machines Eng. Depart., Faculty of Eng., Tanta University, Tanta, Egypt<p class="Abstract"><a name="OLE_LINK15"></a><a name="OLE_LINK14"></a>Towards the complete vision of smarter distribution grid, advanced distribution automation system (ADAS) is one of the major players in this area. In this scope, this paper introduces a generic strategy for cost-effective <a name="OLE_LINK555"></a><a name="OLE_LINK554"></a>implementation and evaluation of ADAS. Along with the same line, fault location, isolation and service restoration (FLISR) is one of the most beneficial and desirable applications of ADAS for self-healing and reliability improvement. Therefore, <a name="OLE_LINK24"></a><a name="OLE_LINK23"></a>a <a name="OLE_LINK567"></a><a name="OLE_LINK566"></a>local-centralized-based FLISR (LC-FLISR) <a name="OLE_LINK677"></a><a name="OLE_LINK676"></a>architecture is implemented on a real, urban, underground medium voltage distribution network. For the investigated network, the complete procedure and structure of the LC-FLISR are presented. Finally, the level of reliability improvement and customers’ satisfaction enhancement are evaluated. The results are presented in the form of a comparative study between the proposed automated and non-automated distribution networks. The results show that the automated network with proposed ADAS has a considerable benefit through a significant reduction in reliability indices. In addition, it has remarkable benefits observed from increasing customers’ satisfaction and reducing penalties from industry regulators.</p>http://apc.aast.edu/ojs/index.php/RESD/article/view/200advanced distribution automation systemfault locationisolation and service restorationself-healing gridrelaibilty assessment study |
spellingShingle | M. R. Elkadeem M. A. Alaam Azmy Azmy Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation Renewable Energy and Sustainable Development advanced distribution automation system fault location isolation and service restoration self-healing grid relaibilty assessment study |
title | Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation |
title_full | Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation |
title_fullStr | Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation |
title_full_unstemmed | Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation |
title_short | Reliability Improvement of Power Distribution Systems using Advanced Distribution Automation |
title_sort | reliability improvement of power distribution systems using advanced distribution automation |
topic | advanced distribution automation system fault location isolation and service restoration self-healing grid relaibilty assessment study |
url | http://apc.aast.edu/ojs/index.php/RESD/article/view/200 |
work_keys_str_mv | AT mrelkadeem reliabilityimprovementofpowerdistributionsystemsusingadvanceddistributionautomation AT maalaam reliabilityimprovementofpowerdistributionsystemsusingadvanceddistributionautomation AT azmyazmy reliabilityimprovementofpowerdistributionsystemsusingadvanceddistributionautomation |