Real-World Efficacy and Safety of the Subcutaneous Implantable Cardioverter Defibrillator: Insights from the GASP Registry

<b>Background:</b> The advent of subcutaneous implantable cardioverter defibrillators (S-ICDs) marked a significant milestone in the course of cardiac rhythm devices, particularly for patients who are deemed at high risk for ventricular arrhythmias and sudden cardiac death. This extracar...

Full description

Saved in:
Bibliographic Details
Main Authors: Nikias Milaras, Evangelos Oikonomou, Konstantinos P. Letsas, Nikolaos Ktenopoulos, Sotirios Xydonas, Panagiotis Korantzopoulos, Georgios Leventopoulos, Panagiotis Dourvas, Stefanos Archontakis, Athena Batsouli, Panagiotis Mililis, Athanasios Saplaouras, Emmanuel Kanoupakis, Konstantinos Toutouzas, Stylianos Paraskevaidis, Michalis Efremidis, Skevos Sideris
Format: Article
Language:English
Published: MDPI AG 2025-06-01
Series:Biomedicines
Subjects:
Online Access:https://www.mdpi.com/2227-9059/13/7/1510
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:<b>Background:</b> The advent of subcutaneous implantable cardioverter defibrillators (S-ICDs) marked a significant milestone in the course of cardiac rhythm devices, particularly for patients who are deemed at high risk for ventricular arrhythmias and sudden cardiac death. This extracardiac approach makes the S-ICD an especially valuable option for young patients, those with difficult venous access, or those at high risk of infection. Although the S-ICD does not provide pacing for bradycardia or heart failure, it has shown efficacy in treating ventricular arrhythmias while minimizing complications associated with transvenous systems. <b>Methods</b>: The purpose of this multicenter retrospective analysis was to assess the real-world efficacy and safety of the S-ICD in a heterogeneous population. <b>Results</b>: The GASP registry consisted of 114 patients, 68% male, aged 41 ± 15 years, with a mean LVEF of 50%. In the follow-up of 35 months, inappropriate shocks occurred in 7% while appropriate shocks occurred in 6.2%. The most common reasons for inappropriate shocks were myopotentials and atrial tachyarrhythmias. Thirty-day complication-free rates were 97.3%, with the majority of patients requiring device extraction due to infection. Over the longer term, four patients required re-intervention due to local discomfort, while one device was extracted for infection. In a multivariate analysis, complications were not significantly higher in the sicker population, such as those with diabetes, kidney disease requiring dialysis, or heart failure. <b>Conclusions</b>: These findings support the growing role of the S-ICD as an alternative to the TV-ICD, especially in patients without pacing indications.