Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study

This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to est...

Full description

Saved in:
Bibliographic Details
Main Authors: Ekhlas A. Abdulkareem, Jwan O. Abdulsattar, Ban O. Abdulsattar
Format: Article
Language:English
Published: University of Baghdad, College of Science for Women 2022-04-01
Series:مجلة بغداد للعلوم
Subjects:
Online Access:https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/5388
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839597602946940928
author Ekhlas A. Abdulkareem
Jwan O. Abdulsattar
Ban O. Abdulsattar
author_facet Ekhlas A. Abdulkareem
Jwan O. Abdulsattar
Ban O. Abdulsattar
author_sort Ekhlas A. Abdulkareem
collection DOAJ
description This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) buffer to yield a reddish/orange colour change proportional to the iron(II) concentration measured at λmax = 510 nm. Under optimum conditions, the calibration curve was linear in the range between (0.5-150) mg L-1 with a limit of detection of 0.09 mg L-1. Compared to a spectrophotometric detection method, µPAD measured colour intensity using captured images using Samsung mobile phone and image J program to give proof of concept that µPAD platform fulfils the purpose of accuracy and at the same time remaining cost-effective and simplistic to be used in both developing and developed countries gave same linear calibration curve with a limit of detection 0.12 mg L-1. ANOVA test was used to compare the proposed method results with conventional method results showing the method was accepted. The antimicrobial activity showed no significant effect from lipstick samples on tested microbes.
format Article
id doaj-art-c33d78f9ff0345bfa1c7c8a50bcc0f15
institution Matheson Library
issn 2078-8665
2411-7986
language English
publishDate 2022-04-01
publisher University of Baghdad, College of Science for Women
record_format Article
series مجلة بغداد للعلوم
spelling doaj-art-c33d78f9ff0345bfa1c7c8a50bcc0f152025-08-02T18:43:33ZengUniversity of Baghdad, College of Science for Womenمجلة بغداد للعلوم2078-86652411-79862022-04-0119210.21123/bsj.2022.19.2.0355Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative StudyEkhlas A. Abdulkareem0Jwan O. Abdulsattar1Ban O. Abdulsattar2Department of Chemistry, College of Science, Diyala University, Diyala, Iraq.Department of Chemistry, College of Science, Mustansiriyah University, Baghdad, Iraq.Department of Biology, College of Science, Mustansiriyah University, Baghdad, Iraq This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) buffer to yield a reddish/orange colour change proportional to the iron(II) concentration measured at λmax = 510 nm. Under optimum conditions, the calibration curve was linear in the range between (0.5-150) mg L-1 with a limit of detection of 0.09 mg L-1. Compared to a spectrophotometric detection method, µPAD measured colour intensity using captured images using Samsung mobile phone and image J program to give proof of concept that µPAD platform fulfils the purpose of accuracy and at the same time remaining cost-effective and simplistic to be used in both developing and developed countries gave same linear calibration curve with a limit of detection 0.12 mg L-1. ANOVA test was used to compare the proposed method results with conventional method results showing the method was accepted. The antimicrobial activity showed no significant effect from lipstick samples on tested microbes. https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/5388Colorimetric, Cosmetic, Heavy metals, Iron (II), µPADs platform, Spectrophotometric.
spellingShingle Ekhlas A. Abdulkareem
Jwan O. Abdulsattar
Ban O. Abdulsattar
Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
مجلة بغداد للعلوم
Colorimetric, Cosmetic, Heavy metals, Iron (II), µPADs platform, Spectrophotometric.
title Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
title_full Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
title_fullStr Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
title_full_unstemmed Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
title_short Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
title_sort iron ii determination in lipstick samples using spectrophotometric and microfluidic paper based analytical device µpads platform via complexation reaction with iron chelator 1 10 phenanthroline a comparative study
topic Colorimetric, Cosmetic, Heavy metals, Iron (II), µPADs platform, Spectrophotometric.
url https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/5388
work_keys_str_mv AT ekhlasaabdulkareem ironiideterminationinlipsticksamplesusingspectrophotometricandmicrofluidicpaperbasedanalyticaldeviceμpadsplatformviacomplexationreactionwithironchelator110phenanthrolineacomparativestudy
AT jwanoabdulsattar ironiideterminationinlipsticksamplesusingspectrophotometricandmicrofluidicpaperbasedanalyticaldeviceμpadsplatformviacomplexationreactionwithironchelator110phenanthrolineacomparativestudy
AT banoabdulsattar ironiideterminationinlipsticksamplesusingspectrophotometricandmicrofluidicpaperbasedanalyticaldeviceμpadsplatformviacomplexationreactionwithironchelator110phenanthrolineacomparativestudy