ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERS

The capacity of power-distributive oil-transformers is selected on the basis of their operational mode cost-effectiveness and power-supply reliability of the electrical recipients on condition that the transformers duty should not lead to reduction of their normal life-in-service. Unconscionable and...

Full description

Saved in:
Bibliographic Details
Main Authors: V. A. Anishchenko, V. V. Ivanov
Format: Article
Language:Russian
Published: Belarusian National Technical University 2015-06-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/861
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839570616915591168
author V. A. Anishchenko
V. V. Ivanov
author_facet V. A. Anishchenko
V. V. Ivanov
author_sort V. A. Anishchenko
collection DOAJ
description The capacity of power-distributive oil-transformers is selected on the basis of their operational mode cost-effectiveness and power-supply reliability of the electrical recipients on condition that the transformers duty should not lead to reduction of their normal life-in-service. Unconscionable and protracted overloads intrinsically decrease reliability and respectively service life of the transformers owing to increased wear of the winding insulation because of the excessive heat. The unaccounted previous loading history and possible changes of the risen overload in the course of its further development can lead to poor accuracy in the admissible overload time estimation. Therefore, that may lead to intolerable excessive heat in the winding insulation or underutilization of the potential overload capacity of the transformers. Which limits the potentiality of complete demand satisfaction of the electrical consumers. This is exactly why the acting GOST 14209–97 strongly recommends the consumers to make their own calculations of the load-carrying capacity based on the real load curves.The authors present a method for ascertainment of the admissible duration of the systematic non-emergency overload of a distributive oil-transformer. The ascertainment method accounts for the overload repetition-factor alteration on the time-interval of its occurrence and respectively the variation in the transformer thermal state. The employment of this method will allow improving accuracy in ascertainment of the admissible duration of the systematic non-emergency overloads and eventually the reliability of the transformer operation and the power-supply system in its entirety. The method realization is intended by means of the transformer-load monitoring as one of the tasks of the electric-energy automated control and accounting system.
format Article
id doaj-art-a8ffb23c55e748c8865eff42dae5c9d5
institution Matheson Library
issn 1029-7448
2414-0341
language Russian
publishDate 2015-06-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-a8ffb23c55e748c8865eff42dae5c9d52025-08-04T14:36:04ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412015-06-0103515843ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERSV. A. Anishchenko0V. V. Ivanov1Belarusian National Technical UniversityBelarusian National Technical UniversityThe capacity of power-distributive oil-transformers is selected on the basis of their operational mode cost-effectiveness and power-supply reliability of the electrical recipients on condition that the transformers duty should not lead to reduction of their normal life-in-service. Unconscionable and protracted overloads intrinsically decrease reliability and respectively service life of the transformers owing to increased wear of the winding insulation because of the excessive heat. The unaccounted previous loading history and possible changes of the risen overload in the course of its further development can lead to poor accuracy in the admissible overload time estimation. Therefore, that may lead to intolerable excessive heat in the winding insulation or underutilization of the potential overload capacity of the transformers. Which limits the potentiality of complete demand satisfaction of the electrical consumers. This is exactly why the acting GOST 14209–97 strongly recommends the consumers to make their own calculations of the load-carrying capacity based on the real load curves.The authors present a method for ascertainment of the admissible duration of the systematic non-emergency overload of a distributive oil-transformer. The ascertainment method accounts for the overload repetition-factor alteration on the time-interval of its occurrence and respectively the variation in the transformer thermal state. The employment of this method will allow improving accuracy in ascertainment of the admissible duration of the systematic non-emergency overloads and eventually the reliability of the transformer operation and the power-supply system in its entirety. The method realization is intended by means of the transformer-load monitoring as one of the tasks of the electric-energy automated control and accounting system.https://energy.bntu.by/jour/article/view/861oil-immersed transformeroverload durationelectric consumerload curve
spellingShingle V. A. Anishchenko
V. V. Ivanov
ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERS
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
oil-immersed transformer
overload duration
electric consumer
load curve
title ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERS
title_full ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERS
title_fullStr ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERS
title_full_unstemmed ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERS
title_short ASCERTAINMENT OF ADMISSIBLE SYSTEMATIC OVERLOADS IN THE DISTRIBUTIVE OIL-TRANSFORMERS
title_sort ascertainment of admissible systematic overloads in the distributive oil transformers
topic oil-immersed transformer
overload duration
electric consumer
load curve
url https://energy.bntu.by/jour/article/view/861
work_keys_str_mv AT vaanishchenko ascertainmentofadmissiblesystematicoverloadsinthedistributiveoiltransformers
AT vvivanov ascertainmentofadmissiblesystematicoverloadsinthedistributiveoiltransformers