Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator

The widespread applying of electrical grids with voltage classes 330 and 750 kV with powerful units of nuclear and heat power plants creates a set of problems with normal modes ensuring in the Ukrainian energy system. Due to sufficiently great transverse capacitance of such overhead lines, significa...

Full description

Saved in:
Bibliographic Details
Main Authors: Kostiantyn Pokrovskyi, Andriy Muzychak
Format: Article
Language:English
Published: Lviv Polytechnic National University 2020-12-01
Series:Energy Engineering and Control Systems
Subjects:
Online Access:https://science.lpnu.ua/jeecs/all-volumes-and-issues/volume-6-number-2-2020/voltage-deviations-influence-asynchronous
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839655623265878016
author Kostiantyn Pokrovskyi
Andriy Muzychak
author_facet Kostiantyn Pokrovskyi
Andriy Muzychak
author_sort Kostiantyn Pokrovskyi
collection DOAJ
description The widespread applying of electrical grids with voltage classes 330 and 750 kV with powerful units of nuclear and heat power plants creates a set of problems with normal modes ensuring in the Ukrainian energy system. Due to sufficiently great transverse capacitance of such overhead lines, significant amounts of reactive power excess are possible in the system. This phenomenon manifests itself especially in the load reduction hours in the power system through the visible voltage levels deviation at the energy-generating nodes in an upward direction. The application of asynchronized turbogenerators with the ability to work in asynchronous mode could solve the problem of reactive power excesses in the energy-generating nodes during load reduction hours in the power system due to their possibility of deep reactive power consumption. The paper presents the calculated results of the asynchronous modes coordinates for an asynchronized turbogenerator with a capacity 1000 MW based on the parameters of the equivalent circuit, taking into account possible generator stator voltage deviations within ±10%. The influence of voltage deviations on the asynchronous modes coordinates is shown. Due to the obtained characteristics, it is possible to perform engineering estimations of the possible asynchronous mode applying for the asynchronized generator under conditions of nuclear and thermal power plants and taking into account possible voltage deviations.
format Article
id doaj-art-a35929c583684d97b87f45bf7b11b543
institution Matheson Library
issn 2411-8028
2415-7287
language English
publishDate 2020-12-01
publisher Lviv Polytechnic National University
record_format Article
series Energy Engineering and Control Systems
spelling doaj-art-a35929c583684d97b87f45bf7b11b5432025-06-25T07:48:18ZengLviv Polytechnic National UniversityEnergy Engineering and Control Systems2411-80282415-72872020-12-01210410910.23939/jeecs2020.02.104Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator Kostiantyn Pokrovskyi0Andriy Muzychak1Lviv Polytechnic National UniversityLviv Polytechnic National UniversityThe widespread applying of electrical grids with voltage classes 330 and 750 kV with powerful units of nuclear and heat power plants creates a set of problems with normal modes ensuring in the Ukrainian energy system. Due to sufficiently great transverse capacitance of such overhead lines, significant amounts of reactive power excess are possible in the system. This phenomenon manifests itself especially in the load reduction hours in the power system through the visible voltage levels deviation at the energy-generating nodes in an upward direction. The application of asynchronized turbogenerators with the ability to work in asynchronous mode could solve the problem of reactive power excesses in the energy-generating nodes during load reduction hours in the power system due to their possibility of deep reactive power consumption. The paper presents the calculated results of the asynchronous modes coordinates for an asynchronized turbogenerator with a capacity 1000 MW based on the parameters of the equivalent circuit, taking into account possible generator stator voltage deviations within ±10%. The influence of voltage deviations on the asynchronous modes coordinates is shown. Due to the obtained characteristics, it is possible to perform engineering estimations of the possible asynchronous mode applying for the asynchronized generator under conditions of nuclear and thermal power plants and taking into account possible voltage deviations.https://science.lpnu.ua/jeecs/all-volumes-and-issues/volume-6-number-2-2020/voltage-deviations-influence-asynchronousasynchronized generatorasynchronous modereactive powergenerator mode
spellingShingle Kostiantyn Pokrovskyi
Andriy Muzychak
Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator
Energy Engineering and Control Systems
asynchronized generator
asynchronous mode
reactive power
generator mode
title Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator
title_full Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator
title_fullStr Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator
title_full_unstemmed Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator
title_short Voltage Deviations Influence on Asynchronous Characteristics of Powerful Asynchronized Turbogenerator
title_sort voltage deviations influence on asynchronous characteristics of powerful asynchronized turbogenerator
topic asynchronized generator
asynchronous mode
reactive power
generator mode
url https://science.lpnu.ua/jeecs/all-volumes-and-issues/volume-6-number-2-2020/voltage-deviations-influence-asynchronous
work_keys_str_mv AT kostiantynpokrovskyi voltagedeviationsinfluenceonasynchronouscharacteristicsofpowerfulasynchronizedturbogenerator
AT andriymuzychak voltagedeviationsinfluenceonasynchronouscharacteristicsofpowerfulasynchronizedturbogenerator