EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITY

Introduction. The manuscript is devoted to the actual problem of thermal insulation of buildings and structures. The paper presents a developed low-density insulation solution with improved heatengineering characteristics. The aim of the work is to increase the efficiency of the heat-shielding syste...

Full description

Saved in:
Bibliographic Details
Main Authors: L. Kh. Zagorodnyuk, D. A. Sumskoy, S. V. Zolotykh
Format: Article
Language:Russian
Published: Siberian State Automobile and Highway University 2019-07-01
Series:Вестник СибАДИ
Subjects:
Online Access:https://vestnik.sibadi.org/jour/article/view/886
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839581595998093312
author L. Kh. Zagorodnyuk
D. A. Sumskoy
S. V. Zolotykh
author_facet L. Kh. Zagorodnyuk
D. A. Sumskoy
S. V. Zolotykh
author_sort L. Kh. Zagorodnyuk
collection DOAJ
description Introduction. The manuscript is devoted to the actual problem of thermal insulation of buildings and structures. The paper presents a developed low-density insulation solution with improved heatengineering characteristics. The aim of the work is to increase the efficiency of the heat-shielding system using a low-density heat-insulating solution.Methods and materials. The authors carried out tests at the site of heat engineering control of LLC «Intellect-service-ZBK-1» to determine the resistance to heat transfer of the enclosing structure.Results. The construction of the wall system consisting of the «Aerobel» D500 gas-silicate block (625×200×250 mm) and made on a low-density heat-insulating masonry mortar, as well as with the use of a heat-insulating mortar and a universal «Moutrical» energy-efficient coating allowed increasing actual reduced heat transfer resistance from 0.9 to 1.4 (m2 ·K) / W (by 36%).Discussion and conclusions. Laboratory research and field tests that meet the requirements of state standards and that develop low-density heat-insulating plaster demonstrate the low-density heatinsulating solution, which indicates the feasibility in thermal insulation of buildings and structures. The authors achieve special economic and ecological effect in connection with the use of local raw materials and waste production of expanded perlite sand.
format Article
id doaj-art-9c5198b979f34b5c8adf017ad5d2cbdd
institution Matheson Library
issn 2071-7296
2658-5626
language Russian
publishDate 2019-07-01
publisher Siberian State Automobile and Highway University
record_format Article
series Вестник СибАДИ
spelling doaj-art-9c5198b979f34b5c8adf017ad5d2cbdd2025-08-04T10:17:44ZrusSiberian State Automobile and Highway UniversityВестник СибАДИ2071-72962658-56262019-07-0116332333310.26518/2071-7296-2019-3-323-333570EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITYL. Kh. Zagorodnyuk0D. A. Sumskoy1S. V. Zolotykh2Belgorod State Technological University named after V.G. ShukhovBelgorod State Technological University named after V.G. ShukhovBelgorod State Technological University named after V.G. ShukhovIntroduction. The manuscript is devoted to the actual problem of thermal insulation of buildings and structures. The paper presents a developed low-density insulation solution with improved heatengineering characteristics. The aim of the work is to increase the efficiency of the heat-shielding system using a low-density heat-insulating solution.Methods and materials. The authors carried out tests at the site of heat engineering control of LLC «Intellect-service-ZBK-1» to determine the resistance to heat transfer of the enclosing structure.Results. The construction of the wall system consisting of the «Aerobel» D500 gas-silicate block (625×200×250 mm) and made on a low-density heat-insulating masonry mortar, as well as with the use of a heat-insulating mortar and a universal «Moutrical» energy-efficient coating allowed increasing actual reduced heat transfer resistance from 0.9 to 1.4 (m2 ·K) / W (by 36%).Discussion and conclusions. Laboratory research and field tests that meet the requirements of state standards and that develop low-density heat-insulating plaster demonstrate the low-density heatinsulating solution, which indicates the feasibility in thermal insulation of buildings and structures. The authors achieve special economic and ecological effect in connection with the use of local raw materials and waste production of expanded perlite sand.https://vestnik.sibadi.org/jour/article/view/886thermal insulationlow density insulation mortarwalling heat transferdry construction mixtures
spellingShingle L. Kh. Zagorodnyuk
D. A. Sumskoy
S. V. Zolotykh
EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITY
Вестник СибАДИ
thermal insulation
low density insulation mortar
walling heat transfer
dry construction mixtures
title EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITY
title_full EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITY
title_fullStr EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITY
title_full_unstemmed EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITY
title_short EFFECTIVE HEAT-PROTECTIVE SYSTEM WITH THE USE OF THERMAL INSULATING SOLUTION OF REDUCED DENSITY
title_sort effective heat protective system with the use of thermal insulating solution of reduced density
topic thermal insulation
low density insulation mortar
walling heat transfer
dry construction mixtures
url https://vestnik.sibadi.org/jour/article/view/886
work_keys_str_mv AT lkhzagorodnyuk effectiveheatprotectivesystemwiththeuseofthermalinsulatingsolutionofreduceddensity
AT dasumskoy effectiveheatprotectivesystemwiththeuseofthermalinsulatingsolutionofreduceddensity
AT svzolotykh effectiveheatprotectivesystemwiththeuseofthermalinsulatingsolutionofreduceddensity