Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model

ABSTRACT Purpose: To evaluate the effectiveness of a new format of prophylactic mesh, with a new method of placement. Methods: Rabbits were randomly distributed into four groups: control rabbits without laparotomy group; sutured rabbits (SR); light-weight mesh rabbits (LWMR); and heavy-weight mesh...

Full description

Saved in:
Bibliographic Details
Main Authors: Thiago de Almeida Furtado, Álvaro Cota Carvalho, Marcelo Lopes Furtado, Luiz Ronaldo Alberti, Diego Paim de Carvalho Garcia
Format: Article
Language:English
Published: Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia 2025-07-01
Series:Acta Cirúrgica Brasileira
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502025000100231&lng=en&tlng=en
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839622125035454464
author Thiago de Almeida Furtado
Álvaro Cota Carvalho
Marcelo Lopes Furtado
Luiz Ronaldo Alberti
Diego Paim de Carvalho Garcia
author_facet Thiago de Almeida Furtado
Álvaro Cota Carvalho
Marcelo Lopes Furtado
Luiz Ronaldo Alberti
Diego Paim de Carvalho Garcia
author_sort Thiago de Almeida Furtado
collection DOAJ
description ABSTRACT Purpose: To evaluate the effectiveness of a new format of prophylactic mesh, with a new method of placement. Methods: Rabbits were randomly distributed into four groups: control rabbits without laparotomy group; sutured rabbits (SR); light-weight mesh rabbits (LWMR); and heavy-weight mesh rabbits (HWMR). The meshes were cut to a size of 10 cm in length by 1 cm in width. A longitudinal, median abdominal incision, 11 cm in length, was performed, followed by an incision over the linea alba, encompassing the entire thickness of the abdominal wall. On the 91st postoperative day, the animals were killed for linea alba scar evaluation. Results: There was a significant difference among the evaluated groups concerning elongation, maximum load, and elasticity modulus. HWMR and LWMR were statistically different from controls regarding elongation. As for the elasticity modulus, SR presented a higher mean when compared to the others. Microscopic visual analysis showed greater fibrotic scarring with a larger amount of implanted material in HWMR. Conclusion: The reinforcement of scars with polypropylene mesh does not increase tensile strength when compared to the use of sutures. Mesh implantation results in scar remodeling with greater fibrosis, leading to increased elongation. However, midline reinforcement using only sutures has greater elasticity than the groups reinforced with mesh.
format Article
id doaj-art-9a3d4c22c4744fc9a66c2d46d20ccc9f
institution Matheson Library
issn 1678-2674
language English
publishDate 2025-07-01
publisher Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
record_format Article
series Acta Cirúrgica Brasileira
spelling doaj-art-9a3d4c22c4744fc9a66c2d46d20ccc9f2025-07-22T07:38:34ZengSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaActa Cirúrgica Brasileira1678-26742025-07-014010.1590/acb405325Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal modelThiago de Almeida Furtadohttps://orcid.org/0000-0003-0380-914XÁlvaro Cota Carvalhohttps://orcid.org/0009-0006-9998-3167Marcelo Lopes Furtadohttps://orcid.org/0000-0002-5103-5807Luiz Ronaldo Albertihttps://orcid.org/0000-0002-5229-3971Diego Paim de Carvalho Garciahttps://orcid.org/0000-0002-2921-653XABSTRACT Purpose: To evaluate the effectiveness of a new format of prophylactic mesh, with a new method of placement. Methods: Rabbits were randomly distributed into four groups: control rabbits without laparotomy group; sutured rabbits (SR); light-weight mesh rabbits (LWMR); and heavy-weight mesh rabbits (HWMR). The meshes were cut to a size of 10 cm in length by 1 cm in width. A longitudinal, median abdominal incision, 11 cm in length, was performed, followed by an incision over the linea alba, encompassing the entire thickness of the abdominal wall. On the 91st postoperative day, the animals were killed for linea alba scar evaluation. Results: There was a significant difference among the evaluated groups concerning elongation, maximum load, and elasticity modulus. HWMR and LWMR were statistically different from controls regarding elongation. As for the elasticity modulus, SR presented a higher mean when compared to the others. Microscopic visual analysis showed greater fibrotic scarring with a larger amount of implanted material in HWMR. Conclusion: The reinforcement of scars with polypropylene mesh does not increase tensile strength when compared to the use of sutures. Mesh implantation results in scar remodeling with greater fibrosis, leading to increased elongation. However, midline reinforcement using only sutures has greater elasticity than the groups reinforced with mesh.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502025000100231&lng=en&tlng=enHernia, VentralModels, AnimalIncisional Hernia
spellingShingle Thiago de Almeida Furtado
Álvaro Cota Carvalho
Marcelo Lopes Furtado
Luiz Ronaldo Alberti
Diego Paim de Carvalho Garcia
Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model
Acta Cirúrgica Brasileira
Hernia, Ventral
Models, Animal
Incisional Hernia
title Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model
title_full Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model
title_fullStr Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model
title_full_unstemmed Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model
title_short Biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh, in an animal model
title_sort biomechanical evaluation of prophylactic reinforcement of the linea alba with a novel method of positioning and fixation of polypropylene mesh in an animal model
topic Hernia, Ventral
Models, Animal
Incisional Hernia
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502025000100231&lng=en&tlng=en
work_keys_str_mv AT thiagodealmeidafurtado biomechanicalevaluationofprophylacticreinforcementofthelineaalbawithanovelmethodofpositioningandfixationofpolypropylenemeshinananimalmodel
AT alvarocotacarvalho biomechanicalevaluationofprophylacticreinforcementofthelineaalbawithanovelmethodofpositioningandfixationofpolypropylenemeshinananimalmodel
AT marcelolopesfurtado biomechanicalevaluationofprophylacticreinforcementofthelineaalbawithanovelmethodofpositioningandfixationofpolypropylenemeshinananimalmodel
AT luizronaldoalberti biomechanicalevaluationofprophylacticreinforcementofthelineaalbawithanovelmethodofpositioningandfixationofpolypropylenemeshinananimalmodel
AT diegopaimdecarvalhogarcia biomechanicalevaluationofprophylacticreinforcementofthelineaalbawithanovelmethodofpositioningandfixationofpolypropylenemeshinananimalmodel