Bench studies of a small axial pump for implantation in patients with low anthropometry

Objective: to conduct bench tests and determine the working range of the pump speed for an implanted left ven- tricular bypass system aimed at diagnosing and treating patients with low anthropometric status.Materials and methods. The axial pump was investigated using a custom-developed hydrodynamic...

Full description

Saved in:
Bibliographic Details
Main Authors: A. S. Buchnev, A. P. Kuleshov, A. A. Drobyshev, V. A. Elenkin, G. A. Shevchenko, N. V. Grudinin
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2025-07-01
Series:Вестник трансплантологии и искусственных органов
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/1942
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839573751538122752
author A. S. Buchnev
A. P. Kuleshov
A. A. Drobyshev
V. A. Elenkin
G. A. Shevchenko
N. V. Grudinin
author_facet A. S. Buchnev
A. P. Kuleshov
A. A. Drobyshev
V. A. Elenkin
G. A. Shevchenko
N. V. Grudinin
author_sort A. S. Buchnev
collection DOAJ
description Objective: to conduct bench tests and determine the working range of the pump speed for an implanted left ven- tricular bypass system aimed at diagnosing and treating patients with low anthropometric status.Materials and methods. The axial pump was investigated using a custom-developed hydrodynamic test bench simulating the cardiovascular system. The bench included systems for pressure and flow measurement and registration, along with software for processing both technical and biomedical parameters.Results. The operating range of the rotor speed for the STREAM CARDIO pump required to achieve a flow rate of 2.5 ± 0.5 L/min at a pressure drop of 80 ± 5 mm Hg is 8000 ± 1000 rpm, with a power consumption of 6.5 ± 1 W.
format Article
id doaj-art-97159ef7abe64d2cb8736421a3135b51
institution Matheson Library
issn 1995-1191
language Russian
publishDate 2025-07-01
publisher Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
record_format Article
series Вестник трансплантологии и искусственных органов
spelling doaj-art-97159ef7abe64d2cb8736421a3135b512025-08-04T14:02:13ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovВестник трансплантологии и искусственных органов1995-11912025-07-01272818810.15825/1995-1191-2025-2-81-881356Bench studies of a small axial pump for implantation in patients with low anthropometryA. S. Buchnev0A. P. Kuleshov1A. A. Drobyshev2V. A. Elenkin3G. A. Shevchenko4N. V. Grudinin5Shumakov National Medical Research Center of Transplantology and Artificial OrgansShumakov National Medical Research Center of Transplantology and Artificial OrgansShumakov National Medical Research Center of Transplantology and Artificial OrgansShumakov National Medical Research Center of Transplantology and Artificial OrgansPeoples’ Friendship University of Russia named after Patrice LumumbaShumakov National Medical Research Center of Transplantology and Artificial OrgansObjective: to conduct bench tests and determine the working range of the pump speed for an implanted left ven- tricular bypass system aimed at diagnosing and treating patients with low anthropometric status.Materials and methods. The axial pump was investigated using a custom-developed hydrodynamic test bench simulating the cardiovascular system. The bench included systems for pressure and flow measurement and registration, along with software for processing both technical and biomedical parameters.Results. The operating range of the rotor speed for the STREAM CARDIO pump required to achieve a flow rate of 2.5 ± 0.5 L/min at a pressure drop of 80 ± 5 mm Hg is 8000 ± 1000 rpm, with a power consumption of 6.5 ± 1 W.https://journal.transpl.ru/vtio/article/view/1942heart failureleft ventricular bypasshydrodynamic benchpump flow ratepump headaxial pump
spellingShingle A. S. Buchnev
A. P. Kuleshov
A. A. Drobyshev
V. A. Elenkin
G. A. Shevchenko
N. V. Grudinin
Bench studies of a small axial pump for implantation in patients with low anthropometry
Вестник трансплантологии и искусственных органов
heart failure
left ventricular bypass
hydrodynamic bench
pump flow rate
pump head
axial pump
title Bench studies of a small axial pump for implantation in patients with low anthropometry
title_full Bench studies of a small axial pump for implantation in patients with low anthropometry
title_fullStr Bench studies of a small axial pump for implantation in patients with low anthropometry
title_full_unstemmed Bench studies of a small axial pump for implantation in patients with low anthropometry
title_short Bench studies of a small axial pump for implantation in patients with low anthropometry
title_sort bench studies of a small axial pump for implantation in patients with low anthropometry
topic heart failure
left ventricular bypass
hydrodynamic bench
pump flow rate
pump head
axial pump
url https://journal.transpl.ru/vtio/article/view/1942
work_keys_str_mv AT asbuchnev benchstudiesofasmallaxialpumpforimplantationinpatientswithlowanthropometry
AT apkuleshov benchstudiesofasmallaxialpumpforimplantationinpatientswithlowanthropometry
AT aadrobyshev benchstudiesofasmallaxialpumpforimplantationinpatientswithlowanthropometry
AT vaelenkin benchstudiesofasmallaxialpumpforimplantationinpatientswithlowanthropometry
AT gashevchenko benchstudiesofasmallaxialpumpforimplantationinpatientswithlowanthropometry
AT nvgrudinin benchstudiesofasmallaxialpumpforimplantationinpatientswithlowanthropometry