Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
The work objective is to study dosing accuracy changes of the vibration measurer with an electromagnetic drive powered by the industrial network. The previously obtained dependences of the vibration measurer performance on the vibration frequency, amplitude and direction of the magnetic actuator, an...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Don State Technical University
2016-06-01
|
Series: | Advanced Engineering Research |
Subjects: | |
Online Access: | https://www.vestnik-donstu.ru/jour/article/view/88 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839577355851399168 |
---|---|
author | Tatyana I. Тupolskikh Natalya V. Gucheva |
author_facet | Tatyana I. Тupolskikh Natalya V. Gucheva |
author_sort | Tatyana I. Тupolskikh |
collection | DOAJ |
description | The work objective is to study dosing accuracy changes of the vibration measurer with an electromagnetic drive powered by the industrial network. The previously obtained dependences of the vibration measurer performance on the vibration frequency, amplitude and direction of the magnetic actuator, and on the properties of the dispensed material are used. These relationships are obtained at the pilot plant with the stabilized power settings. It is found that the supply from the vibration agitator of the industrial network significantly (up to 5%) affects the vibrator meter performance deviation from the given one that may become unacceptable when dispensing the ingredients requiring higher accuracy. To eliminate uncontrolled deviations of the dispenser performance from the stochastic variations of voltage and frequency, a voltage- and frequency-stabilized supply of the vibration activator electromagnet should be used. |
format | Article |
id | doaj-art-958e4e53395b48e5a2072c7aa95ca41f |
institution | Matheson Library |
issn | 2687-1653 |
language | Russian |
publishDate | 2016-06-01 |
publisher | Don State Technical University |
record_format | Article |
series | Advanced Engineering Research |
spelling | doaj-art-958e4e53395b48e5a2072c7aa95ca41f2025-08-04T12:52:54ZrusDon State Technical UniversityAdvanced Engineering Research2687-16532016-06-0116214815310.12737/1968988Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuatorTatyana I. Тupolskikh0Natalya V. Gucheva1Don State Technical UniversityDon State Technical UniversityThe work objective is to study dosing accuracy changes of the vibration measurer with an electromagnetic drive powered by the industrial network. The previously obtained dependences of the vibration measurer performance on the vibration frequency, amplitude and direction of the magnetic actuator, and on the properties of the dispensed material are used. These relationships are obtained at the pilot plant with the stabilized power settings. It is found that the supply from the vibration agitator of the industrial network significantly (up to 5%) affects the vibrator meter performance deviation from the given one that may become unacceptable when dispensing the ingredients requiring higher accuracy. To eliminate uncontrolled deviations of the dispenser performance from the stochastic variations of voltage and frequency, a voltage- and frequency-stabilized supply of the vibration activator electromagnet should be used.https://www.vestnik-donstu.ru/jour/article/view/88дозированиевибрационный дозаторэлектромагнитный приводэлектрическая сетьточность дозированияdispensingvibration measurermagnetic actuatorpower networkmetering accuracy |
spellingShingle | Tatyana I. Тupolskikh Natalya V. Gucheva Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator Advanced Engineering Research дозирование вибрационный дозатор электромагнитный привод электрическая сеть точность дозирования dispensing vibration measurer magnetic actuator power network metering accuracy |
title | Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator |
title_full | Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator |
title_fullStr | Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator |
title_full_unstemmed | Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator |
title_short | Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator |
title_sort | investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator |
topic | дозирование вибрационный дозатор электромагнитный привод электрическая сеть точность дозирования dispensing vibration measurer magnetic actuator power network metering accuracy |
url | https://www.vestnik-donstu.ru/jour/article/view/88 |
work_keys_str_mv | AT tatyanaitupolskikh investigationofpowersupplyparametereffectonperformanceofvibratormeterwithmagneticactuator AT natalyavgucheva investigationofpowersupplyparametereffectonperformanceofvibratormeterwithmagneticactuator |