Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator

The work objective is to study dosing accuracy changes of the vibration measurer with an electromagnetic drive powered by the industrial network. The previously obtained dependences of the vibration measurer performance on the vibration frequency, amplitude and direction of the magnetic actuator, an...

Full description

Saved in:
Bibliographic Details
Main Authors: Tatyana I. Тupolskikh, Natalya V. Gucheva
Format: Article
Language:Russian
Published: Don State Technical University 2016-06-01
Series:Advanced Engineering Research
Subjects:
Online Access:https://www.vestnik-donstu.ru/jour/article/view/88
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839577355851399168
author Tatyana I. Тupolskikh
Natalya V. Gucheva
author_facet Tatyana I. Тupolskikh
Natalya V. Gucheva
author_sort Tatyana I. Тupolskikh
collection DOAJ
description The work objective is to study dosing accuracy changes of the vibration measurer with an electromagnetic drive powered by the industrial network. The previously obtained dependences of the vibration measurer performance on the vibration frequency, amplitude and direction of the magnetic actuator, and on the properties of the dispensed material are used. These relationships are obtained at the pilot plant with the stabilized power settings. It is found that the supply from the vibration agitator of the industrial network significantly (up to 5%) affects the vibrator meter performance deviation from the given one that may become unacceptable when dispensing the ingredients requiring higher accuracy. To eliminate uncontrolled deviations of the dispenser performance from the stochastic variations of voltage and frequency, a voltage- and frequency-stabilized supply of the vibration activator electromagnet should be used.
format Article
id doaj-art-958e4e53395b48e5a2072c7aa95ca41f
institution Matheson Library
issn 2687-1653
language Russian
publishDate 2016-06-01
publisher Don State Technical University
record_format Article
series Advanced Engineering Research
spelling doaj-art-958e4e53395b48e5a2072c7aa95ca41f2025-08-04T12:52:54ZrusDon State Technical UniversityAdvanced Engineering Research2687-16532016-06-0116214815310.12737/1968988Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuatorTatyana I. Тupolskikh0Natalya V. Gucheva1Don State Technical UniversityDon State Technical UniversityThe work objective is to study dosing accuracy changes of the vibration measurer with an electromagnetic drive powered by the industrial network. The previously obtained dependences of the vibration measurer performance on the vibration frequency, amplitude and direction of the magnetic actuator, and on the properties of the dispensed material are used. These relationships are obtained at the pilot plant with the stabilized power settings. It is found that the supply from the vibration agitator of the industrial network significantly (up to 5%) affects the vibrator meter performance deviation from the given one that may become unacceptable when dispensing the ingredients requiring higher accuracy. To eliminate uncontrolled deviations of the dispenser performance from the stochastic variations of voltage and frequency, a voltage- and frequency-stabilized supply of the vibration activator electromagnet should be used.https://www.vestnik-donstu.ru/jour/article/view/88дозированиевибрационный дозаторэлектромагнитный приводэлектрическая сетьточность дозированияdispensingvibration measurermagnetic actuatorpower networkmetering accuracy
spellingShingle Tatyana I. Тupolskikh
Natalya V. Gucheva
Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
Advanced Engineering Research
дозирование
вибрационный дозатор
электромагнитный привод
электрическая сеть
точность дозирования
dispensing
vibration measurer
magnetic actuator
power network
metering accuracy
title Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
title_full Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
title_fullStr Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
title_full_unstemmed Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
title_short Investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
title_sort investigation of power supply parameter effect on performance of vibrator meter with magnetic actuator
topic дозирование
вибрационный дозатор
электромагнитный привод
электрическая сеть
точность дозирования
dispensing
vibration measurer
magnetic actuator
power network
metering accuracy
url https://www.vestnik-donstu.ru/jour/article/view/88
work_keys_str_mv AT tatyanaitupolskikh investigationofpowersupplyparametereffectonperformanceofvibratormeterwithmagneticactuator
AT natalyavgucheva investigationofpowersupplyparametereffectonperformanceofvibratormeterwithmagneticactuator