Failure Analysis on the Impressed Current Cathodic Protection of Wharf Steel Pipe Pile
 The steel pipe piles of a coal wharf were protected by an impressed current cathodic protection system. After construction, it was found that the cathodic protection system was in a state of under - protection regardless of the adjustment of the output current. Therefore, the circuit lay...
Saved in:
Main Author: | LI Hai - hong, DENG Chun - lin, FANG Xiang |
---|---|
Format: | Article |
Language: | Chinese |
Published: |
Editorial Department of Materials Protection
2021-10-01
|
Series: | Cailiao Baohu |
Subjects: | |
Online Access: | http://www.mat-pro.com/fileup/1001-1560/PDF/20211028.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Study on Numerical Simulation of Influence of Sea Mud Resistivity on the Cathodic Protection Effect for Steel Pipe Pile
by: FANG Xiang, ZHANG Dong - fang, FAN Zhi - hong, XIONG Jian - bo
Published: (2021-03-01) -
Impressed current cathodic protection of stainless steel in molten NaOH at 600 °C
by: Birgitte Stoffersen, et al.
Published: (2025-08-01) -
Application of Oilfield Casing Cathodic Protection Technology
by: LIU Li, LIU Jie, ZHANG Yong - qiang, YANG Zhi - gang, LV Shuo, TA Chuan, HUANG Guo - sheng
Published: (2021-03-01) -
Steel bearing piles
by: Cornfield, G.M
Published: (1980) -
Analysis on Leakage Failure of 304 Stainless Steel Pipe
by: HOU Shuai-shuai, ZENG Xian-chen, FU Chun-xia, HU Jia-kun
Published: (2021-08-01)