Demodulation of non-stationary machine vibration using cycle-time scale

Inner time-scale affects the operation of angle demodulator. Can linear approximation of monotonic variations in carrier-cycle improve the recovery of unknown low-energy signal modulating observable vibration processes? Authors make an attempt to answer using phase-locked loop PLL as demodulator. Si...

Full description

Saved in:
Bibliographic Details
Main Authors: P. KRZYWORZEKA, W. CIOCH
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2014-03-01
Series:Archives of Acoustics
Subjects:
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/666
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Inner time-scale affects the operation of angle demodulator. Can linear approximation of monotonic variations in carrier-cycle improve the recovery of unknown low-energy signal modulating observable vibration processes? Authors make an attempt to answer using phase-locked loop PLL as demodulator. Simulations conducted for complex phase model indicate potentially vast possibilities of recognizing and selection of information component. Appropriate selection of approximation time-range enables to achieve acceptable RMS value loads and harmonics of rotational speed of outgoing estimates.
ISSN:0137-5075
2300-262X