Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych Langera

The subject of the considerations are structures composed of beams, arches and connecting elements of which the beams carry also the horizontal force of the arcs. Accurate computation of such structures, called Langer structures, requires considerable labour, which can be reduced by introducing a su...

Full description

Saved in:
Bibliographic Details
Main Author: W. Dzieniszewski
Format: Article
Language:English
Published: Institute of Fundamental Technological Research 1964-03-01
Series:Engineering Transactions
Online Access:https://et.ippt.pan.pl/index.php/et/article/view/2788
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839633179064926208
author W. Dzieniszewski
author_facet W. Dzieniszewski
author_sort W. Dzieniszewski
collection DOAJ
description The subject of the considerations are structures composed of beams, arches and connecting elements of which the beams carry also the horizontal force of the arcs. Accurate computation of such structures, called Langer structures, requires considerable labour, which can be reduced by introducing a suitable scheme with distributed connecting elements. The influence of the external load and temperature changes on the internal forces and displacements of such a system is analysed in the case of axial deformability of all the component elements. The problem reduces to the solution of a Fredholm integral equation of the second kind for the function determining the deflection of the beam due to the forces in the connecting elements. In the numerical example a few diagrams are made for the influence numbers of integral forces and displacements, which are compared with accurate results (with concentrated connection between the arch and the beam) and the solutions obtained by rejecting axial deformability. From the considerations it follows, among other things, that the influence of axial deformability of elements cannot be rejected and that in the case of a great number of connecting elements the introduction of distributed connection of the beam with the arch leads to results of sufficient accuracy.
format Article
id doaj-art-82fd0e9d19fb4ee4b71dce6c22f25a26
institution Matheson Library
issn 0867-888X
2450-8071
language English
publishDate 1964-03-01
publisher Institute of Fundamental Technological Research
record_format Article
series Engineering Transactions
spelling doaj-art-82fd0e9d19fb4ee4b71dce6c22f25a262025-07-11T05:02:49ZengInstitute of Fundamental Technological ResearchEngineering Transactions0867-888X2450-80711964-03-01121Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych LangeraW. Dzieniszewski0Zakład Mechaniki Ośrodków Ciągłych Instytutu Podstawowych Problemów Techniki PANThe subject of the considerations are structures composed of beams, arches and connecting elements of which the beams carry also the horizontal force of the arcs. Accurate computation of such structures, called Langer structures, requires considerable labour, which can be reduced by introducing a suitable scheme with distributed connecting elements. The influence of the external load and temperature changes on the internal forces and displacements of such a system is analysed in the case of axial deformability of all the component elements. The problem reduces to the solution of a Fredholm integral equation of the second kind for the function determining the deflection of the beam due to the forces in the connecting elements. In the numerical example a few diagrams are made for the influence numbers of integral forces and displacements, which are compared with accurate results (with concentrated connection between the arch and the beam) and the solutions obtained by rejecting axial deformability. From the considerations it follows, among other things, that the influence of axial deformability of elements cannot be rejected and that in the case of a great number of connecting elements the introduction of distributed connection of the beam with the arch leads to results of sufficient accuracy. https://et.ippt.pan.pl/index.php/et/article/view/2788
spellingShingle W. Dzieniszewski
Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych Langera
Engineering Transactions
title Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych Langera
title_full Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych Langera
title_fullStr Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych Langera
title_full_unstemmed Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych Langera
title_short Wpływ Sił Podłużnych i Zmian Temperatury na Wielkość Sił Wewnętrznych i Przemieszczeń w Ustrojach Łukowych Langera
title_sort wplyw sil podluznych i zmian temperatury na wielkosc sil wewnetrznych i przemieszczen w ustrojach lukowych langera
url https://et.ippt.pan.pl/index.php/et/article/view/2788
work_keys_str_mv AT wdzieniszewski wpływsiłpodłuznychizmiantemperaturynawielkoscsiłwewnetrznychiprzemieszczenwustrojachłukowychlangera