The Effects of Scan Body Geometry on the Precision and the Trueness of Implant Impressions Using Intraoral Scanners: A Systematic Review
<b>Background/Objectives:</b> Accurate implant impressions are critical for capturing the three-dimensional (3D) spatial positioning of implants. Digital workflows using intraoral scanners (IOSs) and scan bodies offer distinct advantages over conventional elastomeric techniques. However,...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2025-06-01
|
Series: | Dentistry Journal |
Subjects: | |
Online Access: | https://www.mdpi.com/2304-6767/13/6/252 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | <b>Background/Objectives:</b> Accurate implant impressions are critical for capturing the three-dimensional (3D) spatial positioning of implants. Digital workflows using intraoral scanners (IOSs) and scan bodies offer distinct advantages over conventional elastomeric techniques. However, the geometry of scan bodies may influence the precision and trueness of IOS-acquired data, and optimal design parameters remain undefined. This systematic review aims to evaluate the effects of scan body geometry on the trueness of digital implant impressions captured using IOSs. <b>Methods</b>: A systematic search was conducted across PubMed, Scopus, EMBASE, Web of Science, the Cochrane Library, and Google Scholar up to 25 February 2025. Eligible studies assessed the impact of scan body geometry on the accuracy of implant-level impressions acquired with IOSs. Study quality was assessed using the Quality Assessment Tool for In Vitro Studies of Dental Materials (QUIN). <b>Results</b>: Twenty-eight studies were included, of which twenty-six were in vitro. The included studies, published between 2020 and 2025, demonstrated that variations in macro- and micro-geometries influenced both linear and angular trueness. Cylindrical designs with optimal dimensions generally outperformed cuboidal or spherical forms. Structural modifications, such as rigid bar extensions and surface facets, often improved scan accuracy. Some hybrid or modified designs performed comparably to conventional scan bodies. According to QUIN, 27 studies were moderate quality and one had high quality. <b>Conclusions</b>: Scan body geometry affected the accuracy of intraoral implant digital impressions. Designs featuring rigid extensions or simplified geometries improve trueness and precision. Further standardized clinical studies are needed to define optimal design features and validate current in vitro findings. |
---|---|
ISSN: | 2304-6767 |