Research of the Changes in the Structural Group Composition of Transformer Oil During Operation

The actual issue of the electric power industry is the diagnostics of equipment to timely detection of emerging defects and their prevention. The aim of presented work is the development of a method for monitoring the state of transformer equipment based on the determination of structural-group comp...

Full description

Saved in:
Bibliographic Details
Main Authors: KurakinaO.E., KozlovV.K., Turanova O.A., Turanov A.N.
Format: Article
Language:English
Published: Academy of Sciences of Moldova 2018-08-01
Series:Problems of the Regional Energetics
Subjects:
Online Access:http://journal.ie.asm.md/assets/files/05_02_37_2018.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839601486034632704
author KurakinaO.E.
KozlovV.K.
Turanova O.A.
Turanov A.N.
author_facet KurakinaO.E.
KozlovV.K.
Turanova O.A.
Turanov A.N.
author_sort KurakinaO.E.
collection DOAJ
description The actual issue of the electric power industry is the diagnostics of equipment to timely detection of emerging defects and their prevention. The aim of presented work is the development of a method for monitoring the state of transformer equipment based on the determination of structural-group composition of transformer oil. The goal is achieved by measuring spectra of oil in the near-IR (infrared) region. The method of investigation isapproximation of obtained spectra of transformer oils on the basis of reference compoundsspectra.A new method for determining the structural group composition of oils was proposed. It is distinguished by a significant simplicity and directly related to the characteristics of the molecules in comparison with the existing methods for determining the structural group composition from nomograms.Optical spectra in the near-IR range of fresh and used samples of GK transformer oil in the range of 10250-11750 cm-1were recorded and analyzed. It was shown that during the aging transformer oil fraction of CH2-groups decreases, CH3-groups fraction increases somewhat, CH-groups fraction is significantly increased, thereby confirming the effect of increasing the proportion of aromatics in such systems reducing the amount of cycloalkanes, paraffins are most stable. This fact can be used to develop monitoring systems for power oil-filled transformers. Determination of the structural group composition of the oil and its changes during operation will allow monitoring the oil condition, the technical condition of the transformer and to determine the origin of thermal and discharge defects.
format Article
id doaj-art-6b12a32e80f94d289fc58b19b7b71811
institution Matheson Library
issn 1857-0070
language English
publishDate 2018-08-01
publisher Academy of Sciences of Moldova
record_format Article
series Problems of the Regional Energetics
spelling doaj-art-6b12a32e80f94d289fc58b19b7b718112025-08-02T10:16:58ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702018-08-01372394510.5281/zenodo.1343455Research of the Changes in the Structural Group Composition of Transformer Oil During OperationKurakinaO.E.0KozlovV.K.1Turanova O.A.2Turanov A.N.3Kazan State Power EngineeringUniversity, Kazan, Russian FederationKazan State Power EngineeringUniversity, Kazan, Russian FederationKazan E.K. Zavoisky Physical-Technical Institute of the Kazan Scientific Center of the Russian Academy of Sciences, Kazan, Russian FederationKazan E.K. Zavoisky Physical-Technical Institute of the Kazan Scientific Center of the Russian Academy of Sciences, Kazan, Russian FederationThe actual issue of the electric power industry is the diagnostics of equipment to timely detection of emerging defects and their prevention. The aim of presented work is the development of a method for monitoring the state of transformer equipment based on the determination of structural-group composition of transformer oil. The goal is achieved by measuring spectra of oil in the near-IR (infrared) region. The method of investigation isapproximation of obtained spectra of transformer oils on the basis of reference compoundsspectra.A new method for determining the structural group composition of oils was proposed. It is distinguished by a significant simplicity and directly related to the characteristics of the molecules in comparison with the existing methods for determining the structural group composition from nomograms.Optical spectra in the near-IR range of fresh and used samples of GK transformer oil in the range of 10250-11750 cm-1were recorded and analyzed. It was shown that during the aging transformer oil fraction of CH2-groups decreases, CH3-groups fraction increases somewhat, CH-groups fraction is significantly increased, thereby confirming the effect of increasing the proportion of aromatics in such systems reducing the amount of cycloalkanes, paraffins are most stable. This fact can be used to develop monitoring systems for power oil-filled transformers. Determination of the structural group composition of the oil and its changes during operation will allow monitoring the oil condition, the technical condition of the transformer and to determine the origin of thermal and discharge defects.http://journal.ie.asm.md/assets/files/05_02_37_2018.pdf spectroscopya
spellingShingle KurakinaO.E.
KozlovV.K.
Turanova O.A.
Turanov A.N.
Research of the Changes in the Structural Group Composition of Transformer Oil During Operation
Problems of the Regional Energetics
spectroscopy
a
title Research of the Changes in the Structural Group Composition of Transformer Oil During Operation
title_full Research of the Changes in the Structural Group Composition of Transformer Oil During Operation
title_fullStr Research of the Changes in the Structural Group Composition of Transformer Oil During Operation
title_full_unstemmed Research of the Changes in the Structural Group Composition of Transformer Oil During Operation
title_short Research of the Changes in the Structural Group Composition of Transformer Oil During Operation
title_sort research of the changes in the structural group composition of transformer oil during operation
topic spectroscopy
a
url http://journal.ie.asm.md/assets/files/05_02_37_2018.pdf
work_keys_str_mv AT kurakinaoe researchofthechangesinthestructuralgroupcompositionoftransformeroilduringoperation
AT kozlovvk researchofthechangesinthestructuralgroupcompositionoftransformeroilduringoperation
AT turanovaoa researchofthechangesinthestructuralgroupcompositionoftransformeroilduringoperation
AT turanovan researchofthechangesinthestructuralgroupcompositionoftransformeroilduringoperation