Holographic imaging of cylindrical ultrasonic waves

This report is devoted to the visualisation of standing cylindrical ultrasonic wave, generated by a radially vibrating piezoelectric shell, by means of time-average holographic interferometry. The theoretical basis of this technique was introduced, and the expression of light intensity distributi...

Full description

Saved in:
Bibliographic Details
Main Authors: L. Grulkowski, D. Jankowski, P. Kwiek
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2014-01-01
Series:Archives of Acoustics
Subjects:
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/1334
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This report is devoted to the visualisation of standing cylindrical ultrasonic wave, generated by a radially vibrating piezoelectric shell, by means of time-average holographic interferometry. The theoretical basis of this technique was introduced, and the expression of light intensity distribution during holographic reconstruction of cylindrical waves was presented. Finally, the theory was verified by experimental findings. Quite a good agreement between theoretical predictions and experimental results was found.
ISSN:0137-5075
2300-262X