A comparison of direct and indirect splits based on the energy costs

The values of minimum reflux ratio for distillation of zeotropic ternary mixtures were calculated in case of direct and indirect splits. A comparative analysis of these regimes was carried out using the vapor flow criterion. Depending on the feed composition the areas of more favorable process organ...

Full description

Saved in:
Bibliographic Details
Main Authors: P. O. Mavletkulova, L. A. Serafimov, T. V. Arkhipova
Format: Article
Language:Russian
Published: MIREA - Russian Technological University 2013-12-01
Series:Тонкие химические технологии
Subjects:
Online Access:https://www.finechem-mirea.ru/jour/article/view/511
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The values of minimum reflux ratio for distillation of zeotropic ternary mixtures were calculated in case of direct and indirect splits. A comparative analysis of these regimes was carried out using the vapor flow criterion. Depending on the feed composition the areas of more favorable process organization were determined in a concentration simplex. It was concluded that when calculating of minimum reflux it is necessary to consider that the relative volatilities of components are not constant along the apparatus even for ideal mixtures.
ISSN:2410-6593
2686-7575