Forced degradation of metronidazole, oxytetracycline and furazolidone studies using High Performance Liquid Chromatography

The study describes the development of a HPLC -DAD method for the estimation of oxytetracycline and furazolidone in Enteroguard M - powder. The proposed method utilizes a Betasil C 18 column, (4.6 x 250 mm, 5 µm), at 300 C, optimum mobile phase consisted of 40 mM phosphate buffer (pH=7.5): methanol...

Full description

Saved in:
Bibliographic Details
Main Authors: Violeta Tauber (Giugiu), Viorica Chiurciu
Format: Article
Language:English
Published: Asociaţia Naţională a Fabricanţilor de Produse de Uz Veterinar 2014-06-01
Series:Medicamentul Veterinar
Online Access:http://www.veterinarypharmacon.com/docs/1344-2014-VD-8-1-ART.8.EN.pdf