The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma Hyperviscosity
Aim: to test the precision and accuracy of a Digital Microcapillary instrument in measuring blood and plasma viscosity. Methods: about 40 blood samples were drawn for precision test. The samples were obtained from patients admitted for Medical Check-Up at CiptoMangunkusumo Hospital (RSCM) in Decemb...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Interna Publishing
2016-05-01
|
Series: | Acta Medica Indonesiana |
Online Access: | https://actamedindones.org/index.php/ijim/article/view/92 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839618126251032576 |
---|---|
author | Al Rasyid Jusuf Misbach Jan S Purba Ina S Timan Lugyanti Sukrisman Muchtaruddin Mansyur Efta Yudiarsah Suroto Suroto |
author_facet | Al Rasyid Jusuf Misbach Jan S Purba Ina S Timan Lugyanti Sukrisman Muchtaruddin Mansyur Efta Yudiarsah Suroto Suroto |
author_sort | Al Rasyid |
collection | DOAJ |
description |
Aim: to test the precision and accuracy of a Digital Microcapillary instrument in measuring blood and plasma viscosity. Methods: about 40 blood samples were drawn for precision test. The samples were obtained from patients admitted for Medical Check-Up at CiptoMangunkusumo Hospital (RSCM) in December 2011. Accuracy test was evaluated using cross-sectional design and involving 135 patients with acute ischemic stroke. The patients underwent either inpatients or outpatients care at Department of Clinical Pathology, Department of Neurology,and Emergency Unit of RSCM, Fatmawati Hospital Jakarta, Prikasih Hospital Jakarta, and Bhakti Yuda Hospital Depok. The precision test was evaluated by calculating the coefficient of variation (CV), interrater variability of Cronbach Alpha, and reliability coefficient of Bland Altman. The accuracy of the test was evaluated with a diagnostic test. The gold standard used for these tests was Brookfield LV-DV III viscometer. Results: the results of precision test were: CV = 0.04; interrater variability of blood and plasma viscosity = 0.94 and 0.82, respectively; the Bland Altman mean difference = –0.19. The results of accuracy test were: sensitivity of blood and plasma viscosity measurement were 88.9% and 100%, respectively; specificity of blood and plasma viscosity measurement were 88.9% and 84%, respectively. Conclusion: the digital microcapillary has high sensitivity and specificity; therefore the instrument can be considered to be used as screening test tool to measure blood and plasma viscosity.
Key words: digital microcapillary, blood viscosity, plasma viscosity, acute ischemic stroke
|
format | Article |
id | doaj-art-2c76e319b8b44d8aaffb09d4b724c6a8 |
institution | Matheson Library |
issn | 0125-9326 2338-2732 |
language | English |
publishDate | 2016-05-01 |
publisher | Interna Publishing |
record_format | Article |
series | Acta Medica Indonesiana |
spelling | doaj-art-2c76e319b8b44d8aaffb09d4b724c6a82025-07-24T07:03:00ZengInterna PublishingActa Medica Indonesiana0125-93262338-27322016-05-01463The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma HyperviscosityAl Rasyid0Jusuf Misbach1Jan S Purba2Ina S Timan3Lugyanti Sukrisman4Muchtaruddin Mansyur5Efta Yudiarsah6Suroto Suroto7Department of Neurology, Faculty of Medicine, Universitas Indonesia - Cipto Mangunkusumo Hospital, Jakarta, IndonesiaDepartment of Neurology, Faculty of Medicine, Universitas Indonesia - Cipto Mangunkusumo Hospital, Jakarta, IndonesiaDepartment of Neurology, Faculty of Medicine, Universitas Indonesia - Cipto Mangunkusumo Hospital, Jakarta, IndonesiaDepartment of Clinical Pathology, Faculty of Medicine, Universitas Indonesia - Cipto Mangunkusumo Hospital, Jakarta, Indonesia.Department of Internal Medicine, Faculty of Medicine, Universitas Indonesia - Cipto Mangunkusumo Hospital, Jakarta, IndonesiaDepartment of Community Medicine, Faculty of Medicine, Universitas Indonesia,Jakarta, IndonesiaDepartment of Physics, Faculty of Medicine, Universitas Indonesia, Jakarta, IndonesiaDepartment of Neurology, Faculty of Medicine, Universitas Sebelas Maret, Surakarta, Indonesia Aim: to test the precision and accuracy of a Digital Microcapillary instrument in measuring blood and plasma viscosity. Methods: about 40 blood samples were drawn for precision test. The samples were obtained from patients admitted for Medical Check-Up at CiptoMangunkusumo Hospital (RSCM) in December 2011. Accuracy test was evaluated using cross-sectional design and involving 135 patients with acute ischemic stroke. The patients underwent either inpatients or outpatients care at Department of Clinical Pathology, Department of Neurology,and Emergency Unit of RSCM, Fatmawati Hospital Jakarta, Prikasih Hospital Jakarta, and Bhakti Yuda Hospital Depok. The precision test was evaluated by calculating the coefficient of variation (CV), interrater variability of Cronbach Alpha, and reliability coefficient of Bland Altman. The accuracy of the test was evaluated with a diagnostic test. The gold standard used for these tests was Brookfield LV-DV III viscometer. Results: the results of precision test were: CV = 0.04; interrater variability of blood and plasma viscosity = 0.94 and 0.82, respectively; the Bland Altman mean difference = –0.19. The results of accuracy test were: sensitivity of blood and plasma viscosity measurement were 88.9% and 100%, respectively; specificity of blood and plasma viscosity measurement were 88.9% and 84%, respectively. Conclusion: the digital microcapillary has high sensitivity and specificity; therefore the instrument can be considered to be used as screening test tool to measure blood and plasma viscosity. Key words: digital microcapillary, blood viscosity, plasma viscosity, acute ischemic stroke https://actamedindones.org/index.php/ijim/article/view/92 |
spellingShingle | Al Rasyid Jusuf Misbach Jan S Purba Ina S Timan Lugyanti Sukrisman Muchtaruddin Mansyur Efta Yudiarsah Suroto Suroto The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma Hyperviscosity Acta Medica Indonesiana |
title | The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma Hyperviscosity |
title_full | The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma Hyperviscosity |
title_fullStr | The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma Hyperviscosity |
title_full_unstemmed | The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma Hyperviscosity |
title_short | The Role of a Novel Digital Microcapillary Instrument in Detecting Blood and Plasma Hyperviscosity |
title_sort | role of a novel digital microcapillary instrument in detecting blood and plasma hyperviscosity |
url | https://actamedindones.org/index.php/ijim/article/view/92 |
work_keys_str_mv | AT alrasyid theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT jusufmisbach theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT janspurba theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT inastiman theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT lugyantisukrisman theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT muchtaruddinmansyur theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT eftayudiarsah theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT surotosuroto theroleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT alrasyid roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT jusufmisbach roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT janspurba roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT inastiman roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT lugyantisukrisman roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT muchtaruddinmansyur roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT eftayudiarsah roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity AT surotosuroto roleofanoveldigitalmicrocapillaryinstrumentindetectingbloodandplasmahyperviscosity |