EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.

<h4>Introduction</h4>Insulin and C-peptide assessment are important in characterization and management of diabetes. However, their adoption and increased clinical use in low resource settings (LRSs) is partly hindered by logistical factors including supplies required for pre-analytical s...

Full description

Saved in:
Bibliographic Details
Main Authors: Nathan Mubiru, Rogers Mukasa, Isaac Sekitoleko, Priscilla A Balungi, Ronald M Kakumba, Terry Ongaria, Hubert Nkabura, Moffat Nyirenda, Anxious J Niwaha, Wisdom P Nakanga
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2025-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0312065
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839634403371778048
author Nathan Mubiru
Rogers Mukasa
Isaac Sekitoleko
Priscilla A Balungi
Ronald M Kakumba
Terry Ongaria
Hubert Nkabura
Moffat Nyirenda
Anxious J Niwaha
Wisdom P Nakanga
author_facet Nathan Mubiru
Rogers Mukasa
Isaac Sekitoleko
Priscilla A Balungi
Ronald M Kakumba
Terry Ongaria
Hubert Nkabura
Moffat Nyirenda
Anxious J Niwaha
Wisdom P Nakanga
author_sort Nathan Mubiru
collection DOAJ
description <h4>Introduction</h4>Insulin and C-peptide assessment are important in characterization and management of diabetes. However, their adoption and increased clinical use in low resource settings (LRSs) is partly hindered by logistical factors including supplies required for pre-analytical sample handling and limited infrastructure. We aimed to determine the effects of altered sample processing conditions on stability of insulin and C-peptide at the pre-analytical stage.<h4>Methods</h4>Random (non-fasted) blood samples were drawn from ten healthy (glucose range 4.1-8.0 mmol/L) participants. We investigated the mean % change from baseline of C-peptide and insulin in serum (plain tubes) vs plasma (K2EDTA tubes), centrifuged vs uncentrifuged, room vs cool box temperature on the stability of C-peptide and insulin up to 24 hours using Wilcoxon signed rank test. Results were considered clinically significant if the percentage change was > 10% and if the p-value was < 0.05.<h4>Results</h4>Eight patients were included in the final analysis, while two were excluded due to hemolysis. C-peptide and insulin levels stayed above 90% of the baseline concentration in K2EDTA tubes across all storage and processing conditions for up to 24 hours. In contrast, samples collected in plain serum tubes kept at room temperature and uncentrifuged, C-peptide and insulin levels decreased significantly to 51% (p = 0.006) and 62% (p = 0. 083) respectively, similarly insulin levels for centrifuged samples declined to 64% (p = 0.083). All iced and centrifuged serum samples remained above 90% of baseline concentration.<h4>Conclusions</h4>In resource-limited settings where insulin and C-peptide tests are limited to central laboratories and highly dependent on sample referral systems, these tests can be reliably measured without the need for immediate centrifugation or processing from samples collected in whole blood K2EDTA tubes uncentrifuged kept at room temperature and processed within 24hours.
format Article
id doaj-art-2aaf6e8d234a412a885d8f5cafa2bc06
institution Matheson Library
issn 1932-6203
language English
publishDate 2025-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-2aaf6e8d234a412a885d8f5cafa2bc062025-07-10T05:31:40ZengPublic Library of Science (PLoS)PLoS ONE1932-62032025-01-01206e031206510.1371/journal.pone.0312065EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.Nathan MubiruRogers MukasaIsaac SekitolekoPriscilla A BalungiRonald M KakumbaTerry OngariaHubert NkaburaMoffat NyirendaAnxious J NiwahaWisdom P Nakanga<h4>Introduction</h4>Insulin and C-peptide assessment are important in characterization and management of diabetes. However, their adoption and increased clinical use in low resource settings (LRSs) is partly hindered by logistical factors including supplies required for pre-analytical sample handling and limited infrastructure. We aimed to determine the effects of altered sample processing conditions on stability of insulin and C-peptide at the pre-analytical stage.<h4>Methods</h4>Random (non-fasted) blood samples were drawn from ten healthy (glucose range 4.1-8.0 mmol/L) participants. We investigated the mean % change from baseline of C-peptide and insulin in serum (plain tubes) vs plasma (K2EDTA tubes), centrifuged vs uncentrifuged, room vs cool box temperature on the stability of C-peptide and insulin up to 24 hours using Wilcoxon signed rank test. Results were considered clinically significant if the percentage change was > 10% and if the p-value was < 0.05.<h4>Results</h4>Eight patients were included in the final analysis, while two were excluded due to hemolysis. C-peptide and insulin levels stayed above 90% of the baseline concentration in K2EDTA tubes across all storage and processing conditions for up to 24 hours. In contrast, samples collected in plain serum tubes kept at room temperature and uncentrifuged, C-peptide and insulin levels decreased significantly to 51% (p = 0.006) and 62% (p = 0. 083) respectively, similarly insulin levels for centrifuged samples declined to 64% (p = 0.083). All iced and centrifuged serum samples remained above 90% of baseline concentration.<h4>Conclusions</h4>In resource-limited settings where insulin and C-peptide tests are limited to central laboratories and highly dependent on sample referral systems, these tests can be reliably measured without the need for immediate centrifugation or processing from samples collected in whole blood K2EDTA tubes uncentrifuged kept at room temperature and processed within 24hours.https://doi.org/10.1371/journal.pone.0312065
spellingShingle Nathan Mubiru
Rogers Mukasa
Isaac Sekitoleko
Priscilla A Balungi
Ronald M Kakumba
Terry Ongaria
Hubert Nkabura
Moffat Nyirenda
Anxious J Niwaha
Wisdom P Nakanga
EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.
PLoS ONE
title EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.
title_full EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.
title_fullStr EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.
title_full_unstemmed EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.
title_short EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours.
title_sort edta tubes are suitable for insulin and c peptide measurement in resource limited settings and can be stored at room temperature for up to 24 hours
url https://doi.org/10.1371/journal.pone.0312065
work_keys_str_mv AT nathanmubiru edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT rogersmukasa edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT isaacsekitoleko edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT priscillaabalungi edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT ronaldmkakumba edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT terryongaria edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT hubertnkabura edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT moffatnyirenda edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT anxiousjniwaha edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours
AT wisdompnakanga edtatubesaresuitableforinsulinandcpeptidemeasurementinresourcelimitedsettingsandcanbestoredatroomtemperatureforupto24hours