Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy

Brachytherapy is the use of radiotherapy with insertion of radiation sources close to the site that needs treatment. It has become an extremely sought-after option by research fields for its impressive efficiency and practicality. In addition to being a fast-paced procedure, it allows patients to le...

Full description

Saved in:
Bibliographic Details
Main Author: Leonardo Santiago Melgaço Silva
Format: Article
Language:English
Published: Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) 2021-04-01
Series:Brazilian Journal of Radiation Sciences
Subjects:
Online Access:https://bjrs.org.br/revista/index.php/REVISTA/article/view/1476
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839628028768944128
author Leonardo Santiago Melgaço Silva
author_facet Leonardo Santiago Melgaço Silva
author_sort Leonardo Santiago Melgaço Silva
collection DOAJ
description Brachytherapy is the use of radiotherapy with insertion of radiation sources close to the site that needs treatment. It has become an extremely sought-after option by research fields for its impressive efficiency and practicality. In addition to being a fast-paced procedure, it allows patients to leave hospital care very soon after it is done, without pain or with minor discomfort, which can be considered an advantage. The brachytherapy procedure is divided into two stages, obtaining images of the region where seed implantation will take place and the application itself.  The images are obtained by ultrasonography, which will guide the insertion of the needle into the patient's body.  During the injection, the patient is anesthetized and immobilized, so that movements that compromise the accuracy of the needle, which, by the current manual method, are already subject to oscillations are avoided. Currently the application of radioactive seeds is done manually by a clinician who uses needles and monitors their positions through the images generated by ultrasound equipment. Thus, the main objective of this project was to improve the prototype of the Prostate Seed Implantation System (SISP), developed by the Nuclear Engineering Department of the UFMG (Nuclear Engineering Department).  Thus, the device allows automated scanning on x, y and z axes, facilitating the application of radioactive seeds in prostate brachytherapy treatments, which in current treatments are done manually by the clinician. And the possibility of controlling this movement via BLUETOOTH technology.
format Article
id doaj-art-27fe23cae9d941df99a1d35d66358a9c
institution Matheson Library
issn 2319-0612
language English
publishDate 2021-04-01
publisher Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
record_format Article
series Brazilian Journal of Radiation Sciences
spelling doaj-art-27fe23cae9d941df99a1d35d66358a9c2025-07-16T00:59:37ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122021-04-0191A10.15392/bjrs.v9i1A.14761144Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapyLeonardo Santiago Melgaço Silva0Universidade Federal de Minas Gerais - UFMGBrachytherapy is the use of radiotherapy with insertion of radiation sources close to the site that needs treatment. It has become an extremely sought-after option by research fields for its impressive efficiency and practicality. In addition to being a fast-paced procedure, it allows patients to leave hospital care very soon after it is done, without pain or with minor discomfort, which can be considered an advantage. The brachytherapy procedure is divided into two stages, obtaining images of the region where seed implantation will take place and the application itself.  The images are obtained by ultrasonography, which will guide the insertion of the needle into the patient's body.  During the injection, the patient is anesthetized and immobilized, so that movements that compromise the accuracy of the needle, which, by the current manual method, are already subject to oscillations are avoided. Currently the application of radioactive seeds is done manually by a clinician who uses needles and monitors their positions through the images generated by ultrasound equipment. Thus, the main objective of this project was to improve the prototype of the Prostate Seed Implantation System (SISP), developed by the Nuclear Engineering Department of the UFMG (Nuclear Engineering Department).  Thus, the device allows automated scanning on x, y and z axes, facilitating the application of radioactive seeds in prostate brachytherapy treatments, which in current treatments are done manually by the clinician. And the possibility of controlling this movement via BLUETOOTH technology.https://bjrs.org.br/revista/index.php/REVISTA/article/view/1476brachytherapyimplant automatic systemsradioactive seeds.
spellingShingle Leonardo Santiago Melgaço Silva
Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy
Brazilian Journal of Radiation Sciences
brachytherapy
implant automatic systems
radioactive seeds.
title Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy
title_full Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy
title_fullStr Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy
title_full_unstemmed Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy
title_short Development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy
title_sort development of a yz scan system for the improvement of an automatic system of radioactive seed implants in prostate brachytherapy
topic brachytherapy
implant automatic systems
radioactive seeds.
url https://bjrs.org.br/revista/index.php/REVISTA/article/view/1476
work_keys_str_mv AT leonardosantiagomelgacosilva developmentofayzscansystemfortheimprovementofanautomaticsystemofradioactiveseedimplantsinprostatebrachytherapy