An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations

Microwave imaging systems show potential as replacements for commonly used stroke diagnostic systems. We developed and tested a 10-port microwave system on a liquid head phantom with ischemic and hemorrhagic strokes of varying sizes and positions. This system allows for visualization of changes in d...

Full description

Saved in:
Bibliographic Details
Main Authors: Tomas Pokorny, Jan Redr, Hana Laierova, Barbora Smahelova, Jakub Kollar
Format: Article
Language:English
Published: MDPI AG 2025-07-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/25/14/4360
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839615226386841600
author Tomas Pokorny
Jan Redr
Hana Laierova
Barbora Smahelova
Jakub Kollar
author_facet Tomas Pokorny
Jan Redr
Hana Laierova
Barbora Smahelova
Jakub Kollar
author_sort Tomas Pokorny
collection DOAJ
description Microwave imaging systems show potential as replacements for commonly used stroke diagnostic systems. We developed and tested a 10-port microwave system on a liquid head phantom with ischemic and hemorrhagic strokes of varying sizes and positions. This system allows for visualization of changes in dielectric parameters using the TSVD Born approximation, enabling recognition of stroke position and size from the resulting images. The SVM algorithm effectively distinguishes between ischemic and hemorrhagic strokes, achieving 98% accuracy on experimental data, with 99% accuracy in ischemic scenarios and 97% in hemorrhagic scenarios. Using the TSVD Born algorithm, it was possible to precisely image changes in the absolute permittivity of different stroke locations; however, changes in stroke size were more apparent in the variations of absolute permittivity than in the reconstructed stroke size within the antenna plane. Outside this plane, changes in the S-parameters decreased depending on the distance and size of the stroke, making detection and classification more difficult. One ring of antennas around the head proved insufficient, prompting us to focus on developing a system with antennas positioned around the entire head.
format Article
id doaj-art-1bfcce4a75ce4e4fa43f122329897ba3
institution Matheson Library
issn 1424-8220
language English
publishDate 2025-07-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj-art-1bfcce4a75ce4e4fa43f122329897ba32025-07-25T13:36:07ZengMDPI AGSensors1424-82202025-07-012514436010.3390/s25144360An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and LimitationsTomas Pokorny0Jan Redr1Hana Laierova2Barbora Smahelova3Jakub Kollar4Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Praha, Czech RepublicDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Praha, Czech RepublicDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Praha, Czech RepublicDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Praha, Czech RepublicDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Praha, Czech RepublicMicrowave imaging systems show potential as replacements for commonly used stroke diagnostic systems. We developed and tested a 10-port microwave system on a liquid head phantom with ischemic and hemorrhagic strokes of varying sizes and positions. This system allows for visualization of changes in dielectric parameters using the TSVD Born approximation, enabling recognition of stroke position and size from the resulting images. The SVM algorithm effectively distinguishes between ischemic and hemorrhagic strokes, achieving 98% accuracy on experimental data, with 99% accuracy in ischemic scenarios and 97% in hemorrhagic scenarios. Using the TSVD Born algorithm, it was possible to precisely image changes in the absolute permittivity of different stroke locations; however, changes in stroke size were more apparent in the variations of absolute permittivity than in the reconstructed stroke size within the antenna plane. Outside this plane, changes in the S-parameters decreased depending on the distance and size of the stroke, making detection and classification more difficult. One ring of antennas around the head proved insufficient, prompting us to focus on developing a system with antennas positioned around the entire head.https://www.mdpi.com/1424-8220/25/14/4360brain strokemicrowave devicesTSVD Born approximationSVM
spellingShingle Tomas Pokorny
Jan Redr
Hana Laierova
Barbora Smahelova
Jakub Kollar
An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations
Sensors
brain stroke
microwave devices
TSVD Born approximation
SVM
title An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations
title_full An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations
title_fullStr An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations
title_full_unstemmed An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations
title_short An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations
title_sort experimental 10 port microwave system for brain stroke diagnosis potentials and limitations
topic brain stroke
microwave devices
TSVD Born approximation
SVM
url https://www.mdpi.com/1424-8220/25/14/4360
work_keys_str_mv AT tomaspokorny anexperimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT janredr anexperimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT hanalaierova anexperimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT barborasmahelova anexperimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT jakubkollar anexperimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT tomaspokorny experimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT janredr experimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT hanalaierova experimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT barborasmahelova experimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations
AT jakubkollar experimental10portmicrowavesystemforbrainstrokediagnosispotentialsandlimitations