Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary System
[Objective] The busbar interlocking joints of metro rigid overhead catenary system operate for extended periods within the complex coupled vibration system formed between the pantograph and the contact wire. Improper arrangement of intermediate joints can easily lead to issues such as bolt loosening...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | Chinese |
Published: |
Urban Mass Transit Magazine Press
2025-06-01
|
Series: | Chengshi guidao jiaotong yanjiu |
Subjects: | |
Online Access: | https://umt1998.tongji.edu.cn/journal/paper/doi/10.16037/j.1007-869x.20230604.html |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839639961902514176 |
---|---|
author | DAI Hongyu FENG Chao SHEN Zhengchao SANG Guoyang |
author_facet | DAI Hongyu FENG Chao SHEN Zhengchao SANG Guoyang |
author_sort | DAI Hongyu |
collection | DOAJ |
description | [Objective] The busbar interlocking joints of metro rigid overhead catenary system operate for extended periods within the complex coupled vibration system formed between the pantograph and the contact wire. Improper arrangement of intermediate joints can easily lead to issues such as bolt loosening and joint deformation at the connection points, resulting in hard spots, which can further cause excessive wear of the contact wire and arcing phenomena at the joints. Therefore, it is necessary to study the arranging principle for interlocking joints. [Method] The metro rigid overhead catenary system is modeled as an infinite-span continuous beam, and its bending moment is calculated using the finite element method. The optimal installation positions of interlocking joints under different standard span lengths are analyzed. Based on various standard lengths of busbar, the optimal arrangement scheme of interlocking joints within a standard anchoring section is proposed. Additionally, the influence of different installation positions of interlocking joints on the deflection of busbar and the dynamic characteristics of the structure is analyzed. [Result & Conclusion] To ensure a favorable stress condition at the interlocking joints, it is recommended to match the standard span length with the corresponding busbar length, thereby ensuring that all interlocking joints within the anchoring section are installed near the zero-bending-moment points of busbar. The installation position of interlocking joints within a span has a certain impact on the mid-span deflection of busbar, while its influence on the overall structural dynamic characteristics of the anchoring section is negligible. |
format | Article |
id | doaj-art-1a521f7bd24f4f51a08cf97a50092456 |
institution | Matheson Library |
issn | 1007-869X |
language | zho |
publishDate | 2025-06-01 |
publisher | Urban Mass Transit Magazine Press |
record_format | Article |
series | Chengshi guidao jiaotong yanjiu |
spelling | doaj-art-1a521f7bd24f4f51a08cf97a500924562025-07-04T00:48:21ZzhoUrban Mass Transit Magazine PressChengshi guidao jiaotong yanjiu1007-869X2025-06-0128617718110.16037/j.1007-869x.20230604Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary SystemDAI Hongyu0FENG Chao1SHEN Zhengchao2SANG Guoyang3Guangzhou Metro Design & Research Institute Co, Ltd, 510010, Guangzhou, ChinaGuangzhou Metro Design & Research Institute Co, Ltd, 510010, Guangzhou, ChinaGuangzhou Metro Design & Research Institute Co, Ltd, 510010, Guangzhou, ChinaGuangzhou Metro Design & Research Institute Co, Ltd, 510010, Guangzhou, China[Objective] The busbar interlocking joints of metro rigid overhead catenary system operate for extended periods within the complex coupled vibration system formed between the pantograph and the contact wire. Improper arrangement of intermediate joints can easily lead to issues such as bolt loosening and joint deformation at the connection points, resulting in hard spots, which can further cause excessive wear of the contact wire and arcing phenomena at the joints. Therefore, it is necessary to study the arranging principle for interlocking joints. [Method] The metro rigid overhead catenary system is modeled as an infinite-span continuous beam, and its bending moment is calculated using the finite element method. The optimal installation positions of interlocking joints under different standard span lengths are analyzed. Based on various standard lengths of busbar, the optimal arrangement scheme of interlocking joints within a standard anchoring section is proposed. Additionally, the influence of different installation positions of interlocking joints on the deflection of busbar and the dynamic characteristics of the structure is analyzed. [Result & Conclusion] To ensure a favorable stress condition at the interlocking joints, it is recommended to match the standard span length with the corresponding busbar length, thereby ensuring that all interlocking joints within the anchoring section are installed near the zero-bending-moment points of busbar. The installation position of interlocking joints within a span has a certain impact on the mid-span deflection of busbar, while its influence on the overall structural dynamic characteristics of the anchoring section is negligible.https://umt1998.tongji.edu.cn/journal/paper/doi/10.16037/j.1007-869x.20230604.htmlmetrorigid overhead catenarybusbarinterlocking jointarrangement principle |
spellingShingle | DAI Hongyu FENG Chao SHEN Zhengchao SANG Guoyang Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary System Chengshi guidao jiaotong yanjiu metro rigid overhead catenary busbar interlocking joint arrangement principle |
title | Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary System |
title_full | Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary System |
title_fullStr | Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary System |
title_full_unstemmed | Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary System |
title_short | Arrangement Principles of the Busbar Interlocking Joint in Metro Rigid Overhead Catenary System |
title_sort | arrangement principles of the busbar interlocking joint in metro rigid overhead catenary system |
topic | metro rigid overhead catenary busbar interlocking joint arrangement principle |
url | https://umt1998.tongji.edu.cn/journal/paper/doi/10.16037/j.1007-869x.20230604.html |
work_keys_str_mv | AT daihongyu arrangementprinciplesofthebusbarinterlockingjointinmetrorigidoverheadcatenarysystem AT fengchao arrangementprinciplesofthebusbarinterlockingjointinmetrorigidoverheadcatenarysystem AT shenzhengchao arrangementprinciplesofthebusbarinterlockingjointinmetrorigidoverheadcatenarysystem AT sangguoyang arrangementprinciplesofthebusbarinterlockingjointinmetrorigidoverheadcatenarysystem |