CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
The purpose of this publication – to familiarize the readers with the newest achievements in the field of vision machine technologies with regard to the occlusal plethysmography. The principle of plethysmograph work is similar to a principle of mechanical occlusal plethysmograph wo...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Siberian State Medical University (Tomsk)
2013-06-01
|
Series: | Бюллетень сибирской медицины |
Subjects: | |
Online Access: | https://bulletin.ssmu.ru/jour/article/view/347 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839570062254538752 |
---|---|
author | V. I. Kuznetsov S. A. Tarakanov N. I. Ryzhakov |
author_facet | V. I. Kuznetsov S. A. Tarakanov N. I. Ryzhakov |
author_sort | V. I. Kuznetsov |
collection | DOAJ |
description | The purpose of this publication – to familiarize the readers with the newest achievements in the field of vision machine technologies with regard to the occlusal plethysmography. The principle of plethysmograph work is similar to a principle of mechanical occlusal plethysmograph work, with that only a difference that working measuring environment (gas or liquid) is replaced with laser labels, and fixation of change of volume is made by machine vision with the subsequent computer processing. Application of laser technologies of machine vision in future considerably simplified process of diagnostics, will allow to carry out diagnostics repeatedly and under various conditions of, for example, case of external action on the examined finiteness of the of heat, cold, physical exercise, and so, is representative of more and accurate picture of the state of blood vessels in the dynamics. |
format | Article |
id | doaj-art-0d6e6d1b39b84a4b80837ef7ab766c6a |
institution | Matheson Library |
issn | 1682-0363 1819-3684 |
language | English |
publishDate | 2013-06-01 |
publisher | Siberian State Medical University (Tomsk) |
record_format | Article |
series | Бюллетень сибирской медицины |
spelling | doaj-art-0d6e6d1b39b84a4b80837ef7ab766c6a2025-08-04T16:45:36ZengSiberian State Medical University (Tomsk)Бюллетень сибирской медицины1682-03631819-36842013-06-0112311712010.20538/1682-0363-2013-3-117-120343CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHODV. I. Kuznetsov0S. A. Tarakanov1N. I. Ryzhakov2National Research University of Information Technologies, Mechanics and Opticians, St. PetersburgNational Research University of Information Technologies, Mechanics and Opticians, St. PetersburgNational Research University of Information Technologies, Mechanics and Opticians, St. PetersburgThe purpose of this publication – to familiarize the readers with the newest achievements in the field of vision machine technologies with regard to the occlusal plethysmography. The principle of plethysmograph work is similar to a principle of mechanical occlusal plethysmograph work, with that only a difference that working measuring environment (gas or liquid) is replaced with laser labels, and fixation of change of volume is made by machine vision with the subsequent computer processing. Application of laser technologies of machine vision in future considerably simplified process of diagnostics, will allow to carry out diagnostics repeatedly and under various conditions of, for example, case of external action on the examined finiteness of the of heat, cold, physical exercise, and so, is representative of more and accurate picture of the state of blood vessels in the dynamics.https://bulletin.ssmu.ru/jour/article/view/347mechanical occlusal plethysmographytechnologies of machine vision in medicine |
spellingShingle | V. I. Kuznetsov S. A. Tarakanov N. I. Ryzhakov CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD Бюллетень сибирской медицины mechanical occlusal plethysmography technologies of machine vision in medicine |
title | CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD |
title_full | CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD |
title_fullStr | CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD |
title_full_unstemmed | CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD |
title_short | CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD |
title_sort | contactless measurement of key parameters of limb vessels on an occlusal plethysmography method |
topic | mechanical occlusal plethysmography technologies of machine vision in medicine |
url | https://bulletin.ssmu.ru/jour/article/view/347 |
work_keys_str_mv | AT vikuznetsov contactlessmeasurementofkeyparametersoflimbvesselsonanocclusalplethysmographymethod AT satarakanov contactlessmeasurementofkeyparametersoflimbvesselsonanocclusalplethysmographymethod AT niryzhakov contactlessmeasurementofkeyparametersoflimbvesselsonanocclusalplethysmographymethod |