CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD

The purpose of this publication – to familiarize the readers with the newest achievements in the field of vision   machine   technologies   with   regard to the   occlusal   plethysmography.   The   principle   of plethysmograph work is similar to a principle of mechanical occlusal plethysmograph wo...

Full description

Saved in:
Bibliographic Details
Main Authors: V. I. Kuznetsov, S. A. Tarakanov, N. I. Ryzhakov
Format: Article
Language:English
Published: Siberian State Medical University (Tomsk) 2013-06-01
Series:Бюллетень сибирской медицины
Subjects:
Online Access:https://bulletin.ssmu.ru/jour/article/view/347
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1839570062254538752
author V. I. Kuznetsov
S. A. Tarakanov
N. I. Ryzhakov
author_facet V. I. Kuznetsov
S. A. Tarakanov
N. I. Ryzhakov
author_sort V. I. Kuznetsov
collection DOAJ
description The purpose of this publication – to familiarize the readers with the newest achievements in the field of vision   machine   technologies   with   regard to the   occlusal   plethysmography.   The   principle   of plethysmograph work is similar to a principle of mechanical occlusal plethysmograph work, with that only a difference that working measuring environment (gas or liquid) is replaced with laser labels, and fixation of change of volume is made by machine vision with the subsequent computer processing. Application of laser technologies of machine vision in future considerably simplified process of diagnostics, will allow to carry out diagnostics repeatedly and under various conditions of, for example, case of external action on the examined finiteness of the of heat, cold, physical exercise, and so, is representative of more and accurate picture of the state of blood vessels in the dynamics.
format Article
id doaj-art-0d6e6d1b39b84a4b80837ef7ab766c6a
institution Matheson Library
issn 1682-0363
1819-3684
language English
publishDate 2013-06-01
publisher Siberian State Medical University (Tomsk)
record_format Article
series Бюллетень сибирской медицины
spelling doaj-art-0d6e6d1b39b84a4b80837ef7ab766c6a2025-08-04T16:45:36ZengSiberian State Medical University (Tomsk)Бюллетень сибирской медицины1682-03631819-36842013-06-0112311712010.20538/1682-0363-2013-3-117-120343CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHODV. I. Kuznetsov0S. A. Tarakanov1N. I. Ryzhakov2National Research University of Information Technologies, Mechanics and Opticians, St. PetersburgNational Research University of Information Technologies, Mechanics and Opticians, St. PetersburgNational Research University of Information Technologies, Mechanics and Opticians, St. PetersburgThe purpose of this publication – to familiarize the readers with the newest achievements in the field of vision   machine   technologies   with   regard to the   occlusal   plethysmography.   The   principle   of plethysmograph work is similar to a principle of mechanical occlusal plethysmograph work, with that only a difference that working measuring environment (gas or liquid) is replaced with laser labels, and fixation of change of volume is made by machine vision with the subsequent computer processing. Application of laser technologies of machine vision in future considerably simplified process of diagnostics, will allow to carry out diagnostics repeatedly and under various conditions of, for example, case of external action on the examined finiteness of the of heat, cold, physical exercise, and so, is representative of more and accurate picture of the state of blood vessels in the dynamics.https://bulletin.ssmu.ru/jour/article/view/347mechanical occlusal plethysmographytechnologies of machine vision in medicine
spellingShingle V. I. Kuznetsov
S. A. Tarakanov
N. I. Ryzhakov
CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
Бюллетень сибирской медицины
mechanical occlusal plethysmography
technologies of machine vision in medicine
title CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
title_full CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
title_fullStr CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
title_full_unstemmed CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
title_short CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
title_sort contactless measurement of key parameters of limb vessels on an occlusal plethysmography method
topic mechanical occlusal plethysmography
technologies of machine vision in medicine
url https://bulletin.ssmu.ru/jour/article/view/347
work_keys_str_mv AT vikuznetsov contactlessmeasurementofkeyparametersoflimbvesselsonanocclusalplethysmographymethod
AT satarakanov contactlessmeasurementofkeyparametersoflimbvesselsonanocclusalplethysmographymethod
AT niryzhakov contactlessmeasurementofkeyparametersoflimbvesselsonanocclusalplethysmographymethod