Dosimetry in CR mammography using radiochromic film
To estimate the dose that a patient's mammary tissue receives during mammographic screening, radiochromic film and objects simulators made of PMMA are used. This material interacts with X-rays in a similar way to tissue. Estimating the dose absorbed by a tissue is important to verify that the d...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
2022-12-01
|
Series: | Brazilian Journal of Radiation Sciences |
Subjects: | |
Online Access: | https://bjrs.org.br/revista/index.php/REVISTA/article/view/2013 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1839628076589252608 |
---|---|
author | Mabel Bustos Flores Arnaldo Prata Mourão Samuel Queiroz Pelegrineli Juraci Passos dos Reis Junior |
author_facet | Mabel Bustos Flores Arnaldo Prata Mourão Samuel Queiroz Pelegrineli Juraci Passos dos Reis Junior |
author_sort | Mabel Bustos Flores |
collection | DOAJ |
description | To estimate the dose that a patient's mammary tissue receives during mammographic screening, radiochromic film and objects simulators made of PMMA are used. This material interacts with X-rays in a similar way to tissue. Estimating the dose absorbed by a tissue is important to verify that the dose is within the recommended limits and in this way minimize the undesirable effects that radiation can cause and optimize the radiation dose that patients receive. This work aims to estimate the dose deposited in the breast tissue that a patient can receive during a mammographic screening, when a mammography device with a CR detection system is used. PMMA plates were used as simulator object and radiochromic film to measure the dose from its calibration curve. The dosimetric test was performed on the upper, lower surface and between the plates of the object. |
format | Article |
id | doaj-art-0d22591c38fa4af3a3d40b37eb2c24b2 |
institution | Matheson Library |
issn | 2319-0612 |
language | English |
publishDate | 2022-12-01 |
publisher | Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) |
record_format | Article |
series | Brazilian Journal of Radiation Sciences |
spelling | doaj-art-0d22591c38fa4af3a3d40b37eb2c24b22025-07-16T00:44:54ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122022-12-01103B (Suppl.)10.15392/2319-0612.2022.20131631Dosimetry in CR mammography using radiochromic filmMabel Bustos Flores0Arnaldo Prata Mourão1Samuel Queiroz Pelegrineli2Juraci Passos dos Reis JuniorUniversidade Federal de Minas Gerais Departamento de Engenharia NuclearFederal University of Minas GeraisFaculdade Bezerra de AraújoTo estimate the dose that a patient's mammary tissue receives during mammographic screening, radiochromic film and objects simulators made of PMMA are used. This material interacts with X-rays in a similar way to tissue. Estimating the dose absorbed by a tissue is important to verify that the dose is within the recommended limits and in this way minimize the undesirable effects that radiation can cause and optimize the radiation dose that patients receive. This work aims to estimate the dose deposited in the breast tissue that a patient can receive during a mammographic screening, when a mammography device with a CR detection system is used. PMMA plates were used as simulator object and radiochromic film to measure the dose from its calibration curve. The dosimetric test was performed on the upper, lower surface and between the plates of the object.https://bjrs.org.br/revista/index.php/REVISTA/article/view/2013dosimetrymammographycomputed radiographysimulator object |
spellingShingle | Mabel Bustos Flores Arnaldo Prata Mourão Samuel Queiroz Pelegrineli Juraci Passos dos Reis Junior Dosimetry in CR mammography using radiochromic film Brazilian Journal of Radiation Sciences dosimetry mammography computed radiography simulator object |
title | Dosimetry in CR mammography using radiochromic film |
title_full | Dosimetry in CR mammography using radiochromic film |
title_fullStr | Dosimetry in CR mammography using radiochromic film |
title_full_unstemmed | Dosimetry in CR mammography using radiochromic film |
title_short | Dosimetry in CR mammography using radiochromic film |
title_sort | dosimetry in cr mammography using radiochromic film |
topic | dosimetry mammography computed radiography simulator object |
url | https://bjrs.org.br/revista/index.php/REVISTA/article/view/2013 |
work_keys_str_mv | AT mabelbustosflores dosimetryincrmammographyusingradiochromicfilm AT arnaldopratamourao dosimetryincrmammographyusingradiochromicfilm AT samuelqueirozpelegrineli dosimetryincrmammographyusingradiochromicfilm AT juracipassosdosreisjunior dosimetryincrmammographyusingradiochromicfilm |